liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Visually Supporting Multiple Needle Placement in Irreversible Electroporation Interventions
Visual Computing Group, Ulm University, Ulm, Germany.
Karolinska Institutet Stockholm, Stockholm, Sweden.
Visual Computing Group, Ulm University, Ulm, Germany.ORCID-id: 0000-0002-7857-5512
2018 (engelsk)Inngår i: Computer Graphics Forum, Vol. 37, nr 6, s. 59-71Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Irreversible electroporation (IRE) is a minimally invasive technique for small tumour ablation. Multiple needles are inserted around the planned treatment zone and, depending on the size, inside as well. An applied electric field triggers instant cell death around this zone. To ensure the correct application of IRE, certain criteria need to be fulfilled. The needles' placement in the tissue has to be parallel, at the same depth, and in a pattern which allows the electric field to effectively destroy the targeted lesions. As multiple needles need to synchronously fulfill these criteria, it is challenging for the surgeon to perform a successful IRE. Therefore, we propose a visualization which exploits intuitive visual coding to support the surgeon when conducting IREs. We consider two scenarios: first, to monitor IRE parameters while inserting needles during laparoscopic surgery; second, to validate IRE parameters in post‐placement scenarios using computed tomography. With the help of an easy to comprehend and lightweight visualization, surgeons are enabled to quickly visually detect what needs to be adjusted. We have evaluated our visualization together with surgeons to investigate the practical use for IRE liver ablations. A quantitative study shows the effectiveness compared to a single 3D view placement method.

sted, utgiver, år, opplag, sider
Wiley-Blackwell Publishing Inc., 2018. Vol. 37, nr 6, s. 59-71
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-152563DOI: 10.1111/cgf.13311ISI: 000437272800004Scopus ID: 2-s2.0-85038627097OAI: oai:DiVA.org:liu-152563DiVA, id: diva2:1261284
Merknad

(EuroVis Fast Track Revision)

Tilgjengelig fra: 2018-11-06 Laget: 2018-11-06 Sist oppdatert: 2018-11-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Ropinski, Timo

Søk i DiVA

Av forfatter/redaktør
Ropinski, Timo

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 285 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf