liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Glycerol monooleate-blood interactions
Linköpings universitet, Institutionen för fysik, kemi och biologi. Linköpings universitet, Tekniska högskolan.
Linköpings universitet, Institutionen för klinisk och experimentell medicin. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Laboratoriemedicinskt centrum, Klinisk kemi.
St Paul, USA.
Linköpings universitet, Institutionen för fysik, kemi och biologi. Linköpings universitet, Tekniska högskolan.
Vise andre og tillknytning
2009 (engelsk)Inngår i: Colloids and Surfaces B: Biointerfaces, ISSN 0927-7765, E-ISSN 1873-4367, Vol. 68, nr 1, s. 20-26Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In the present study the initial blood compatibility of glycerol monooleate (GMO)-coated surfaces was evaluated after deposition to surfaces and in bulk. The model surface was silica onto which multiple layers of fibrinogen or human serum albumin (HSA) was immobilized. The protein-coated surfaces were subsequently dip-coated in GMO in ethanol and used for blood plasma and whole blood experiments. The characterization methods included null ellipsometry, scanning electron microscopy, imaging of coagulation, hemolysis test and whole blood coagulation time by free oscillation rheometry.

The results showed a GMO film thickness of approximately 350 angstrom (similar to 4 mu g/cm(2)) upon dip-coating in ethanolic solution. A major part of the deposited layer detached in aqueous solutions, especially during shear conditions. The coagulation time on GMO was significantly prolonged compared to that on HSA coated silica. Whole blood tests showed that GMO is a very weak hemolytic agent. Deposited GMO detached easily from surfaces upon rinsing or shearing, although a stable layer with undefined phase structure and a thickness of 50-70 angstrom remained on HSA and fibrinogen precoated surfaces. This indicates that GMO has stronger adhesive forces to its substrate compared to the cohesive forces acting within the bulk GMO. The ability of GMO to detach from itself and tentatively form micelles or lipid bilayers when subjected to flowing blood may be of use in extravascular applications. It is concluded that GMO results in weak blood activation, and the material may in spite of this be suitable in selected biomaterial applications, especially as a biosealant and in colloidal dispersions.

sted, utgiver, år, opplag, sider
2009. Vol. 68, nr 1, s. 20-26
Emneord [en]
Glycerol monooleate, Blood compatibility, Shear, Ellipsometry
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-16356DOI: 10.1016/j.colsurfb.2008.09.016OAI: oai:DiVA.org:liu-16356DiVA, id: diva2:133973
Tilgjengelig fra: 2009-01-16 Laget: 2009-01-16 Sist oppdatert: 2017-12-14bibliografisk kontrollert
Inngår i avhandling
1. Imaging methods for haemostasis research
Åpne denne publikasjonen i ny fane eller vindu >>Imaging methods for haemostasis research
2009 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Blood is a vital part of the human physiology; a transport system that brings nutrients and oxygen to sustain living cells and simultaneously facilitates the removal of carbon dioxide and other waste products from the body. To assure the continuity of these functions, it is of uttermost importance to keep the flowing blood inside the vascular system at any cost. The principal components of the haemostatic system are the blood platelets and the plasma coagulation system, both working in concert to create a blood stopping haemostatic plug when a vessel is ruptured. In modern health care, methods for treatment and diagnostics often implicate the contact between blood and artificial materials (biomaterials). Biomaterial surfaces may activate platelets and the coagulation cascade by exposing a surface that during blood contact shares certain characteristics with surfaces found at the site of vascular injury. Therefore it is of great importance that the mechanisms behind the interactions between foreign surfaces and blood are studied in order to minimize, and if possible, prevent unnecessary reactions that may lead to thrombosis.

This thesis describes two important methods to study blood – surface interactions in terms of surface induced plasma coagulation and platelet adhesion/aggregation. The method ‘Imaging of coagulation’, a coagulation assay based on time-lapse image capture of the coagulation process was developed during the course of this work. The use of images enables the method to answer questions regarding where coagulation was initiated and how fast coagulation propagates. Such questions are highly relevant in the study of blood-biomaterial interactions but also in general haemostasis research. In vivo, platelet adhesion and aggregation are events that always proceed under flow conditions. Therefore we also developed a cone-and-plate flow model to study these mechanisms under similar conditions in vitro. The cone-and-plate setup was found to be a flexible platform and was used for both blood compatibility testing of potential biomaterials as well as for general haemostasis research.

With the above mentioned methods we tested the haemocompatibility of glycerol monooleate (GMO), a proposed substance for use in biomaterial applications. It was found that GMO did not activate coagulation to any great extent either in plasma or in whole blood.

Surface induced coagulation and platelet adhesion was also studied on PEG-containing hydrogels and compared with hydrogels constructed from three different non-PEG-containing monomers. It was concluded that all the grafted hydrogels, in particular those produced from the monomers 2-hydroxyethyl methacrylate (HEMA) and/or PEG- methacrylate (PEGMA), demonstrated good haemocompatibility.

Supported phospholipid bilayers were used to investigate the relationship between surface charge and procoagulant activity. The coagulation process was studied in a straightforward manner using the imaging of coagulation setup. We concluded that the content of negatively charged 1-palmitoyl-2-oleoyl-sn-glycero-3-[phospho-L-serine] (POPS) in the bilayer must exceed ~ 6% for the bilayer to exert procoagulant activity.

The physiological role of factor XII in human haemostasis and thrombosis was investigated in the imaging of coagulation setup and the cone and plate setup by the use of surfaces with thrombogenic coatings. We found that tissue factor initiated coagulation could be greatly accelerated by the presence of contact activating agents in a platelet dependent manner.

In conclusion, the method ‘Imaging of coagulation’ and platelet adhesion/aggregation in the cone-and-plate flow model are both versatile methods with many possible applications. The combination of the two methods provides a solid foundation for biomaterial and haemostasis research.

sted, utgiver, år, opplag, sider
Linköping: Linköping University Electronic Press, 2009. s. 61
Serie
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1131
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-19178 (URN)978-91-7393-621-7 (ISBN)
Disputas
2009-06-01, Aulan, Hälsans hus, Campus US, Linköpings Universitet, Linköping, 13:00 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2009-06-12 Laget: 2009-06-12 Sist oppdatert: 2020-02-26bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstLink to Ph.D. Thesis

Person

Ericsson, EmmaFaxälv, LarsAskendal, AgnetaLindahl, TomasTengvall, Pentti

Søk i DiVA

Av forfatter/redaktør
Ericsson, EmmaFaxälv, LarsAskendal, AgnetaLindahl, TomasTengvall, Pentti
Av organisasjonen
I samme tidsskrift
Colloids and Surfaces B: Biointerfaces

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 532 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf