liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Up to 10-year follow-up after EVAR with the Endurant stent graft system: a single-center experience
Isala, Netherlands.
Region Östergötland, Hjärtcentrum, Thorax-kärlkliniken i Östergötland.
Isala, Netherlands.
Isala, Netherlands.
Vise andre og tillknytning
2021 (engelsk)Inngår i: Journal of Cardiovascular Surgery, ISSN 0021-9509, E-ISSN 1827-191X, Vol. 62, nr 3, s. 242-249Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: Endovascular aneurysm repair (EVAR) has become the preferred treatment for infrarenal abdominal aortic aneurysms (AAA) over open surgical repair. The Endurant stent graft is widely used, and large registries report low rates of aneurysm-related mortality and reinterventions at midterm follow-up. Reports of long-term follow-up are limited. The aim of this study is to report our experiences and share our results. reintervention rate and mortality at long-term follow-up after using the Endurant stent graft. METHODS: All consecutive patients treated between 2009 and 2013 with the Medtronic Endurant I and II stent graft for an infrarenal AAA in an elective setting were included. Primary outcomes were overall and aneurysm-related survival and reintervention rates. RESULTS: One hundred sixty-five consecutive patients (median age 74; IQR: 68-79) with an aneurysm diameter of 62 mm (IQR: 58-70) and neck length of 29 mm (IQR: 21-40) were electively treated with the Endurant 1 or II stent graft. One hundred thirty-four patients (81.2%) were treated inside IFU (instructions for use) and 31 (18.8%) outside IFU. At median follow-up of 76 months (IQR: 50-97), 60 patients (36.4%) were deceased. Kaplan-Meier estimates at 10 years follow-up of overall survival and freedom from aneurysm-related mortality were respectively 48.5% (CI: 43.7-53.3%) and 973% (CI: 95.7-98.9%). Freedom from reintervention was 86.0% with an CI: 83.1-88.9% at 5 years follow-up and 75.6% with a CI: 70.2-81.0% at 10 years follow-up. A total of 25 (15.2%) patients had an EVAR-related reintervention; indications were endoleak (EL) type 1A (N.=11), EL type 1B (N.=3), EL type 2 (N.=6), EL type 3 (N.=1) and limb occlusion (N.=4). We found no significant differences in outcome between the inside and outside IFU groups. At 5 years follow-up 92.6% of patients had stable or decreased diameter, and 7.4% had an increased diameter. CONCLUSIONS: This large cohort single-center study demonstrates the effectiveness and safety of the Endurant stent graft system at long-term follow-up with low reintervention rates and aneurysm-related mortality.

sted, utgiver, år, opplag, sider
EDIZIONI MINERVA MEDICA , 2021. Vol. 62, nr 3, s. 242-249
Emneord [en]
Aortic aneurysm; abdominal; Endovascular procedures; Vascular surgical procedures
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-175962DOI: 10.23736/S0021-9509.21.11643-XISI: 000647926500007PubMedID: 33635041Scopus ID: 2-s2.0-85105798641OAI: oai:DiVA.org:liu-175962DiVA, id: diva2:1558885
Tilgjengelig fra: 2021-06-01 Laget: 2021-06-01 Sist oppdatert: 2025-06-09

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Søk i DiVA

Av forfatter/redaktør
Lind, Robert C.
Av organisasjonen
I samme tidsskrift
Journal of Cardiovascular Surgery

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 57 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf