liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Psychometric evaluation of the implantable cardioverter defibrillator body image concerns questionnaire (ICD-BICQ)
Univ Southern Denmark, Denmark; Odense Univ Hosp, Denmark; Odense Univ Hosp, Denmark; Univ Southern Denmark, Denmark.
Odense Univ Hosp, Denmark.
Odense Univ Hosp, Denmark; Univ Southern Denmark, Denmark.
Linköpings universitet, Institutionen för hälsa, medicin och vård, Avdelningen för omvårdnad och reproduktiv hälsa. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärtcentrum, Kardiologiska kliniken US. Odense Univ Hosp, Denmark.ORCID-id: 0000-0002-4259-3671
Vise andre og tillknytning
2021 (engelsk)Inngår i: Cardiovascular Electrophysiology, ISSN 1045-3873, E-ISSN 1540-8167, Vol. 32, nr 8, s. 2295-2311Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: Patients receiving an implantable cardioverter defibrillator (ICD) generally adapt well to living with their device, but we know little about the prevalence of patients body image concerns (BICs) postimplant. Methods: The objectives were to evaluate the psychometric properties of the ICD-body image concerns questionnaire (BICQ), find a cut-off indicating BICs and determine the prevalence of BICs. Construct validity was determined using the Kaiser-Meyer-Olkin test, Scree-plot and explorative factor analysis. Internal consistency was examined via Cronbachs alpha. Correlations to other validated questionnaires, a weighted and simple scale and a cut-off indicating BICs was evaluated. Results: In total, 331 patients completed the 39-item ICD-BICQ together with: Type D Scale (DS14), Generalized Anxiety Disorder scale (GAD-7), Patient Health Questionnaire (PHQ-9), and Florida Patient Acceptance Survey. Five patients were excluded due to reoperations, leaving 326 patients in the analyses. Results revealed a one-factor structure with 32 items and Cronbachs alpha at.948. A cut-off at 36 points displayed the 20% patients with the highest score of BICs. The prevalence was 29.8% in women and 18.4% in men. Conclusion: The psychometric evaluation of the 32-item ICD-BICQ showed acceptable construct validity and internal reliability. We recommend a cut-off score at 36 points to identify patients at risk of having BICs. The prevalence of BICs indicated that both men and women are at risk of having BICs. The ICD-BICQ can be used in clinical practice to help healthcare professionals to identify patients at risk of BICs and as to evaluate BICs when implementing new operation techniques.

sted, utgiver, år, opplag, sider
WILEY , 2021. Vol. 32, nr 8, s. 2295-2311
Emneord [en]
body image concerns; implantable cardioverter defibrillator; prevalence questionnaire
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-177433DOI: 10.1111/jce.15122ISI: 000661172000001PubMedID: 34091980OAI: oai:DiVA.org:liu-177433DiVA, id: diva2:1574851
Tilgjengelig fra: 2021-06-29 Laget: 2021-06-29 Sist oppdatert: 2025-02-10

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Strömberg, Anna
Av organisasjonen
I samme tidsskrift
Cardiovascular Electrophysiology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 64 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf