liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Evaluation of venous plasma glucose measured by point-of-care testing (Accu-Chek Inform II) and a hospital laboratory hexokinase method (Cobas c701) in oral glucose tolerance testing during pregnancy - a challenge in diagnostic accuracy
Linköpings universitet, Institutionen för biomedicinska och kliniska vetenskaper, Avdelningen för cellbiologi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Diagnostikcentrum, Klinisk kemi.
Linköpings universitet, Institutionen för biomedicinska och kliniska vetenskaper, Avdelningen för barns och kvinnors hälsa. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Barn- och kvinnocentrum, Kvinnokliniken ViN.ORCID-id: 0000-0002-6249-4259
Linköpings universitet, Institutionen för biomedicinska och kliniska vetenskaper, Avdelningen för klinisk kemi och farmakologi. Linköpings universitet, Medicinska fakulteten.
Linköpings universitet, Institutionen för biomedicinska och kliniska vetenskaper, Avdelningen för barns och kvinnors hälsa. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Barn- och kvinnocentrum, Kvinnokliniken US.
Vise andre og tillknytning
2021 (engelsk)Inngår i: Scandinavian Journal of Clinical and Laboratory Investigation, ISSN 0036-5513, E-ISSN 1502-7686, Vol. 81, nr 8, s. 607-614Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

To diagnose gestational diabetes mellitus (GDM), plasma glucose measurements during oral glucose tolerance test (OGTT) put high demands on the methods in terms of accuracy. The aim was to evaluate and compare diagnostic performance of a point-of-care test and a glucose hexokinase laboratory method. Using risk-based screening, 175 pregnant women were included. They underwent a 75 g OGTT in their 28th (median) week of gestation. Venous blood was collected in two different tubes. Plasma glucose was measured on Cobas c701 and in duplicates on AccuChek Inform II (both methods from Roche Diagnostics). Accuracy was assessed by participating in external control programs with reference method assigned values. The methods were compared for all samples (n = 512) by regression analysis; slope of 0.90 (95% CI: 0.89-0.92), intercept of 0.12 (95% CI: 0.011-0.22) and r(s) of 0.968. The average bias between AccuChek Inform II and Cobas c701 was -8%. The proportion of women diagnosed with GDM was 25% based on AccuChek Inform II versus 55% for Cobas c701. Results from the external control program showed a bias of approximately 5% for Cobas c701 and no significant bias for AccuChek Inform II. Cobas c701 showed a large bias both towards Accu-Chek Inform II and the reference method used in the external control program, clearly exceeding the desirable bias of <2.6%. The lack of accuracy has great implications on either over- or under-diagnosis of GDM.

sted, utgiver, år, opplag, sider
Taylor & Francis, 2021. Vol. 81, nr 8, s. 607-614
Emneord [en]
Plasma glucose; oral glucose tolerance test; gestational diabetes mellitus; accuracy; point-of-care testing; pregnancy
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-179857DOI: 10.1080/00365513.2021.1980224ISI: 000698934900001PubMedID: 34559593OAI: oai:DiVA.org:liu-179857DiVA, id: diva2:1600666
Merknad

Funding Agencies|ALF Region Ostergotland, Sweden [LIO-531111]

Tilgjengelig fra: 2021-10-05 Laget: 2021-10-05 Sist oppdatert: 2025-02-11

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Person

Ekman, Bertil

Søk i DiVA

Av forfatter/redaktør
Landberg, EvaNevander, SofiaHadi, MohammedBlomberg, MarieEkman, BertilLilliecreutz, Caroline
Av organisasjonen
I samme tidsskrift
Scandinavian Journal of Clinical and Laboratory Investigation

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 174 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf