liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Cryo-EM reconstruction of the chlororibosome to 3.2Å resolution within 24h
Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, Solna, Sweden.ORCID-id: 0000-0002-6247-4063
Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, Solna, Sweden.
Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, Solna, Sweden.
Science for Life Laboratory, Department of Biochemistry and Biophysics, Stockholm University, Solna, Sweden.
Vise andre og tillknytning
2017 (engelsk)Inngår i: IUCrJ, E-ISSN 2052-2525, IUCrJ, Vol. 4, nr 6, s. 723-727Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The introduction of direct detectors and the automation of data collection in cryo-EM have led to a surge in data, creating new opportunities for advancing computational processing. In particular, on-the-fly workflows that connect data collection with three-dimensional reconstruction would be valuable for more efficient use of cryo-EM and its application as a sample-screening tool. Here, accelerated on-the-fly analysis is reported with optimized organization of the data-processing tools, image acquisition and particle alignment that make it possible to reconstruct the three-dimensional density of the 70S chlororibosome to 3.2Å resolution within 24h of tissue harvesting. It is also shown that it is possible to achieve even faster processing at comparable quality by imposing some limits to data use, as illustrated by a 3.7Å resolution map that was obtained in only 80min on a desktop computer. These on-the-fly methods can be employed as an assessment of data quality from small samples and extended to high-throughput approaches.

sted, utgiver, år, opplag, sider
International Union Of Crystallography, 2017. Vol. 4, nr 6, s. 723-727
Emneord [en]
cryo-EM, image processing, chlororibosome
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-207028DOI: 10.1107/S205225251701226XOAI: oai:DiVA.org:liu-207028DiVA, id: diva2:1892958
Tilgjengelig fra: 2024-08-28 Laget: 2024-08-28 Sist oppdatert: 2024-12-04bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Forsberg, Björn O.

Søk i DiVA

Av forfatter/redaktør
Forsberg, Björn O.
I samme tidsskrift
IUCrJ

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 10 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf