A Randomized Double-Blinded Clinical Study of Early Volumetric Changes After Shunt Surgery and MRI-Resistance of the Codman Certas® Plus Shunt Valve
Linköpings universitet, Institutionen för biomedicinska och kliniska vetenskaper, Avdelningen för cell- och neurobiologi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Sinnescentrum, Neurokirurgiska kliniken US.
Linköpings universitet, Institutionen för biomedicinska och kliniska vetenskaper. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Sinnescentrum, Neurokirurgiska kliniken US.
Linköpings universitet, Institutionen för hälsa, medicin och vård, Avdelningen för diagnostik och specialistmedicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Diagnostikcentrum, Röntgenkliniken i Linköping. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Lund Univ, Sweden.ORCID-id: 0000-0001-8850-3742
Linköpings universitet, Institutionen för biomedicinska och kliniska vetenskaper, Avdelningen för kirurgi, ortopedi och onkologi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Sinnescentrum, Neurokirurgiska kliniken US.ORCID-id: 0000-0003-3982-7745
2025 (engelsk)Inngår i: World Neurosurgery, ISSN 1878-8750, E-ISSN 1878-8769, Vol. 202, artikkel-id 124424Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

<black square> OBJECTIVE: Linear radiological measures have low sensitivity to detect changes in ventricular volume in patients with idiopathic normal pressure hydrocephalus. Ventricular volumetry is accurate and sensitive in detecting subtle changes in cerebrospinal fluid volumes. The Codman Certas (R) Plus is an adjustable shunt valve with 8 settings and resistant to magnetic resonance imaging (MRI)-induced inadvertent adjustments in vitro. The aim of this study was to investigate early volumetric changes in ventricles after ventriculoperitoneal shunting in relation to shunt setting and linear measures. We also wanted to evaluate the MRI-resistance of the Codman Certas (R) Plus valve in a clinical setting. <black square> METHODS: Forty-five idiopathic normal pressure hydrocephalus patients underwent quantitative MRI, including volumetry before and 36 hours after shunting with Codman Certas (R) Plus valves set to 4 (20 patients) and 8 (25 patients). Valve setting was blinded to patients and examiners and assessed after each MRI. Patients performed in total 156 MRI examinations during 3 years. <black square> RESULTS: There was significant difference in change of ventricular volume between groups 4 and 8 early after surgery. Patients with setting 4 had a ventricular volume reduction of 16 (standard deviation +/- 9) mL while those with setting 8 had a reduction of 5 (standard deviation +/- 5) mL. Constriction of subarachnoid cerebrospinal fluid spaces in cerebral high convexity and parafalcine sulci was significantly less in the setting 4 group postoperatively. There were no MRI-induced changes to valve setting after any MRI. <black square> CONCLUSIONS: Ventricular volumetry can detect shunt-induced reduction in ventricle volume early after surgery. The magnitude of reduction is related to shunt valve resistance. The Codman Certas (R) Plus valve is stable against MRI-induced changes in a clinical setting.

sted, utgiver, år, opplag, sider
ELSEVIER SCIENCE INC , 2025. Vol. 202, artikkel-id 124424
Emneord [en]
Codman Certas (R) plus shunt valve; Idiopathic normal pressure hydrocephalus; Quantitative MRI; Radscale; Ventriculoperitoneal shunt; Volumetry; Tight high convexity
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-218769DOI: 10.1016/j.wneu.2025.124424ISI: 001582421900002PubMedID: 40887008Scopus ID: 2-s2.0-105016515893OAI: oai:DiVA.org:liu-218769DiVA, id: diva2:2006971
Merknad

Funding Agencies|Linkoping University Hospital Research Fund

Tilgjengelig fra: 2025-10-16 Laget: 2025-10-16 Sist oppdatert: 2026-02-09
Inngår i avhandling
1. Volumetrics and proteomics in idiopathic normal pressure hydrocephalus
Åpne denne publikasjonen i ny fane eller vindu >>Volumetrics and proteomics in idiopathic normal pressure hydrocephalus
2026 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Idiopathic normal pressure hydrocephalus (iNPH) is a common and treatable neurological disorder in older adults with ventriculomegaly due to disturbed cerebrospinal fluid (CSF) dynamics. The pathophysiology of iNPH is still incompletely understood, and there is growing evidence that neuroinflammation is partly responsible. Ventricular size is radiologically assessed with linear measures such as the Evans index (EI), but these measures are insensitive to clinically relevant changes in ventricular volume, so postoperative monitoring remains challenging. Shunt treatment is frequently complicated by overdrainage, underdrainage and suspected malfunction.

The overall aim of this thesis was to develop and evaluate a clinically feasible quantitative tool for monitoring shunt treatment and apply it in a clinical cohort of iNPH patients with a special focus on the following: 1. Ventricular volumetry based on 3D quantitative MRI (qMRI). 2. Very early postoperative ventricular change in relation to initial valve setting and in vivo MRI resistance of a modern adjustable shunt valve. 3. Long-term relationships between volumetric change, clinical response and overdrainage 4. Inflammatory and neurodegenerative biomarker profiles in iNPH patients across plasma, lumbar CSF and ventricular CSF.

The LiNPH study, a prospective controlled clinical longitudinal cohort study with a randomized controlled trial component, provided the data for the four papers in this thesis. Paper I was a methodological reliability study (45 qMRI examinations from iNPH patients and controls) comparing manual, automated and reviewed ventricular segmentations. Paper II was a randomized, double-blinded clinical study (n=45) with qMRI volumetry preoperatively and ~36 hours post-operatively that compared Certas Plus shunt valve settings 4 (open shunt) versus 8 (virtually closed) and evaluated the in vivo MRI stability of the valve. Paper III was a prospective cohort study (50 enrolled; follow-up at 3, 12 and 36 months) relating ventricular volumetry to clinical outcomes, valve adjustments and complications. Paper IV utilized CSF and plasma samples collected preoperatively from iNPH patients (n=56) and neurologically healthy controls (n=19) to profile 71 inflammatory cytokines, chemokines, growth factors and classical neurodegenerative markers, including paired plasma, lumbar CSF and ventricular CSF, via multiplex immunoassays and multivariate modelling.

qMRI-based ventricular volumetry demonstrated excellent intra- and interrater reliability (intraclass correlation coefficient 0.999--1.000), whereas EI failed to reflect several clinically important volume differences. Early after shunting, ventricular volumes decreased significantly in both randomized groups, but the reduction was greater at setting 4 than at setting 8 (mean 16±9 mL vs 5±5 mL), whereas linear measures were equal except for THC (tight high convexity, the amount of CSF in the parasagittal convexity sulci). There were no inadvertent valve adjustments after 156 MRI examinations were performed. Over three years, the mean ventricular volume decreased from 134±35 mL preoperatively to 97±31 mL at 36 months, whereas gait and the iNPH scale improved markedly early and remained improved at the group level. Compared with nonresponders, responders presented greater reductions, and patients with overdrainage symptoms (orthostatic headaches and more) presented greater reductions than asymptomatic patients did. Biomarker analyses revealed a robust iNPH inflammatory profile compared with that of the controls and strong compartment concentration separation.

In conclusion, qMRI-based ventricular volumetry is a sensitive, reliable and clinically feasible method for longitudinal iNPH follow-up, providing clinically valuable information on shunt effects, valve adjustments, suspicion of malfunction and overdrainage risk. The Codman Certas Plus valve is MRI resistant in vivo. There is a clear inflammatory component in iNPH pathophysiology, and there are substantial differences in cytokine and neurodegenerative biomarker concentrations among ventricular CSF, lumbar CSF and plasma, which are relevant to future study designs.

Abstract [sv]

Idiopatisk normaltryckshydrocefalus (iNPH) är en neurologisk sjukdom hos äldre och kan ge gång- och balanssvårigheter, kognitiv svikt och inkontinensbesvär. Vid sjukdomen är hjärnans vätskefyllda hålrum (ventriklar) vidgade och cirkulationen av cerebrospinalvätska (CSF) är störd. Nya studier tyder på att inflammation i nervsystemet kan bidra till sjukdomsutvecklingen. Många patienter förbättras efter shuntoperation där CSF leds bort. Nuvarande röntgenmetoder är bra för diagnos men är för trubbiga för att följa ventrikelstorlek och shuntfunktion postoperativt. De enkla mått som används på datortomografi och magnetresonanstomografi (MRI), t ex Evans index (EI), missar viktiga förändringar. Samtidigt kan shuntbehandling orsaka komplikationer som överdränage av CSF, underfunktion av shunten samt shuntstopp. Ventrikelvolymmätning kan vara ett bättre och känsligare sätt att följa ventriklarnas storleksförändring.

Syftet med denna avhandling var att utveckla och utvärdera en mer exakt och praktiskt användbar metod för att följa shuntbehandling vid iNPH och tillämpa den på patienter. Fokus låg på: 1. automatisk och tillförlitlig mätning av ventrikelvolym med 3D kvantitativ MRI-teknik (qMRI). 2. Tidiga förändringar av ventrikelvolym efter shuntoperation i relation till motståndet på en modern ställbar shuntventil samt dess förmåga att motstå förändringar av motståndet av MRI. 3. Hur ventrikelvolymen förändras i relation till klinisk förbättring, överdränage och förändrat ventilmotstånd under tre års uppföljning av iNPH-patienter. 4. Förekomst av inflammatoriska (cytokiner/kemokiner) och neurodegenerativa proteiner (s k biomarkörer) hos iNPH-patienter jämfört med friska försökspersoner i blod och CSF tagen från ländryggen (L-CSF) samt ventriklarna (V-CSF).

En klinisk studie, LiNPH-studien, genomfördes under tre år och gav upphov till fyra artiklar: Artikel 1 var en metodutvecklingsstudie som jämförde manuell bedömning av ventrikelvolymen med automatiserad och eftergranskad. Artikel 2 var en randomiserad dubbelblind studie med qMRI före och ca 36 timmar efter operation där två motstånd (shunten Certas Plus motstånd 4 (öppen) respektive 8 (virtuellt avstängd)) jämfördes och ventilens MR-stabilitet följdes. Artikel 3 var en prospektiv uppföljningsstudie med kontroller av kliniska tester och ventrikelvolym innan operationen samt vid 3-, 12- och 36 månader efteråt. Artikel 4 analyserade 71 cytokiner/kemokiner samt neurogenerativa biomarkörer hos iNPH-patienter och friska försökspersoner.

qMRI-baserad ventrikelvolym visade mycket hög mätprecision och tydliga skillnader medan EI missade att påvisa dessa. Redan 36 timmar efter shuntoperation sågs en tydlig volymminskning i båda grupperna men större vid motstånd 4 än 8. EI och nästan alla vanligen använda mått var oförändrade. Efter 156 MRI-undersökningar kunde ingen oavsiktlig ventilomställning påvisas. Under tre år minskade ventrikelvolymen tydligt med drygt en fjärdedel samtidigt som iNPH-symtomen förbättrades tydligt, särskilt gång och balans. Patienter som förbättrades på shuntbehandlingen hade oftast större volymsminskning än icke-svarande medan överdränerade patienter hade ännu större volymsminskning. Biomarkörstudien visade tydliga skillnader i proteiners koncentrationer mellan blod, L-CSF samt V-CSF samt mellan patienter och friska försökspersoner. Därtill kunde ett mönster förenligt med neuroinflammation påvisas hos iNPH-patienterna.

Sammanfattningsvis visar avhandlingen att qMRI-baserad ventrikelvolymsmätning är en pålitlig och kliniskt genomförbar metod för långsiktig uppföljning av iNPH-patienter. Metoden kan ge stöd vid bedömning av shunteffekt, ventilmotståndjusteringar, misstänkt shuntstopp och risk för överdränage. Certas Plus-ventilen är motståndskraftig mot MRI i klinisk praxis. Det finns ett tydligt neuroinflammatoriskt inslag vid iNPH:s sjukdomsutveckling och skillnaderna mellan koncentrationer mellan provtagningsställena behöver beaktas i framtida forskningsstudier.

sted, utgiver, år, opplag, sider
Linköping: Linköping University Electronic Press, 2026. s. 159
Serie
Linköping University Medical Dissertations, ISSN 0345-0082 ; 2014
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-221083 (URN)10.3384/9789181183351 (DOI)9789181183344 (ISBN)9789181183351 (ISBN)
Disputas
2026-03-06, Berzeliussalen, building 463, Campus US, Linköping, 09:00 (svensk)
Opponent
Veileder
Tilgjengelig fra: 2026-02-09 Laget: 2026-02-09 Sist oppdatert: 2026-02-09bibliografisk kontrollert

Open Access i DiVA

fulltext(3477 kB)52 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 3477 kBChecksum SHA-512
9255725879b3b47fc7baa6793e025c19ec9b635851e086ba37aefe93f86d1feb50a1a627eb6d02037d8367c7c4711efae44ebd3d87a6475e59d3409f3ec8ad29
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMedScopus

Søk i DiVA

Av forfatter/redaktør
Holmgren, RafaelNilsson, MartinGeorgiopoulos, CharalamposZsigmond, Peter
Av organisasjonen
I samme tidsskrift
World Neurosurgery

Søk utenfor DiVA

GoogleGoogle Scholar
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 183 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf