liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Chronic Liver Disease: Assessing Inflammation and Fibrosis Using Three‐Dimensional MR Elastography With Same‐Day Biopsy in a Prospective Cohort
Linköpings universitet, Institutionen för hälsa, medicin och vård, Avdelningen för diagnostik och specialistmedicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.ORCID-id: 0000-0002-5713-6385
Linköpings universitet, Institutionen för hälsa, medicin och vård. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Institutionen för medicinsk teknik, Avdelningen för medicinsk teknik. Linköpings universitet, Tekniska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.ORCID-id: 0000-0003-3805-1674
Linköpings universitet, Institutionen för hälsa, medicin och vård, Avdelningen för diagnostik och specialistmedicin. Linköpings universitet, Medicinska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV.ORCID-id: 0000-0002-9876-8274
Linköpings universitet, Institutionen för hälsa, medicin och vård, Avdelningen för diagnostik och specialistmedicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Centrum för kirurgi, ortopedi och cancervård, Mag- tarmmedicinska kliniken.ORCID-id: 0000-0003-4223-8968
Vise andre og tillknytning
2026 (engelsk)Inngår i: Journal of Magnetic Resonance Imaging, ISSN 1053-1807, E-ISSN 1522-2586, Vol. 64, nr 1, s. 306-319, artikkel-id jmri.70319Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: Three-dimensional (3D) MR elastography (MRE) derives viscoelastic parameters that may reflect inflammation, but their frequency dependence and the influence of steatosis on inflammation grading and fibrosis staging remain unclear.

Purpose: To investigate 3D multifrequency MRE for assessing hepatic inflammation, fibrosis stage across frequencies, and the influence of steatosis.

Study Type: Prospective.

Population: Sixty-four (40 men, median age: 58 years) participants with chronic liver disease (CLD); 21 (8 men, median age:28 years) healthy volunteers.

Field Strength/Sequence: 3-T; gradient-echo sequence with mechanical vibrations at low (16.7 and 18 Hz), medium (33.4 and 36 Hz), and high (50.1 and 54 Hz) frequencies.

Assessment: In CLD participants, MRE-derived viscoelastic parameters, shear stiffness, storage modulus, loss modulus, and damping ratio were compared with histologically assessed fibrosis, inflammation, and steatosis. MRE test–retest repeatability over 10 min was evaluated in healthy volunteers.

Statistical Tests: Wilcoxon rank sum test, Spearman's correlation, multivariable regression analysis, and area under the receiver operating curve (AUROC). A p value of < 0.05 was considered statistically significant.

Results: Inflammation was significantly independently associated with damping ratio at medium frequency, which showed moderate performance for grading inflammation (AUROC = 0.76–0.83, sensitivity = 0.83–0.84, specificity = 0.70–0.79). Fibrosis staging using shear stiffness and moduli showed high diagnostic performance (AUROC = 0.82–0.95), with comparable accuracy between medium and high frequencies (p = 0.327–0.896). Steatosis was not significantly correlated with MRE overall (p = 0.212–0.459), but was significantly associated with 19% higher stiffness and 20% higher loss modulus at medium frequency in CLD participants without fibrosis or inflammation.

Data Conclusion: Medium frequency 3D MRE demonstrated an independent association with inflammation while preserving accurate fibrosis assessment. Steatosis seemed not to confound MRE-based evaluation.

Level of Evidence: 1.

Technical Efficacy: Stage 2.

Plain Language Summary: Chronic liver disease can cause both inflammation and scarring (fibrosis). Accurate assessment usually requires a biopsy, which is invasive. This study evaluated a noninvasive imaging method called three-dimensional magnetic resonance elastography (3D MRE) in patients who underwent same-day liver biopsy. The researchers tested whether different vibration frequencies could detect inflammation and fibrosis. They found that medium frequency measurements were associated with liver inflammation while still accurately identifying fibrosis. Fat accumulation in the liver did not significantly affect the results. These findings suggest that 3D MRE may help medical doctors assess liver inflammation and fibrosis noninvasively in a single examination.

sted, utgiver, år, opplag, sider
John Wiley & Sons, 2026. Vol. 64, nr 1, s. 306-319, artikkel-id jmri.70319
Emneord [en]
Chronic liver disease, Fibrosis, Inflammation, MR elastography, Steatosis
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-222446DOI: 10.1002/jmri.70319ISI: 001732121800001PubMedID: 41924972Scopus ID: 2-s2.0-105034898236OAI: oai:DiVA.org:liu-222446DiVA, id: diva2:2050614
Merknad

Funding: This work was supported by Vinnova (Sweden's Innovation Agency), the Swedish Research Council for Engineering Sciences and Natural Sciences (VR/NT), 2020-04826, and ALF funding (Avtal om Läkarutbildning och Forskning; Agreement on Medical Education and Research) from Region Östergötland (Östergötland County Council).

Tilgjengelig fra: 2026-04-02 Laget: 2026-04-02 Sist oppdatert: 2026-06-26

Open Access i DiVA

fulltext(2371 kB)18 nedlastinger
Filinformasjon
Fil FULLTEXT02.pdfFilstørrelse 2371 kBChecksum SHA-512
4a8cf8965aa9c87400cda760aa33c99ba3490529eaa6189f87b4c3eab968e42c3ab44aed4c3b255a40dc5004489a6824207da847cd1945431432edcbd5acf303
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMedScopus

Person

Cai, ShanSimonsson, ChristianKarlsson, MarkusBalkhed, WileTellman, JensIgnatova, SimoneNasr, PatrikEkstedt, MattiasKechagias, StergiosBartholomä, WolfDahlström, NilsLundberg, Peter

Søk i DiVA

Av forfatter/redaktør
Cai, ShanSimonsson, ChristianKarlsson, MarkusBalkhed, WileTellman, JensIgnatova, SimoneNasr, PatrikEkstedt, MattiasKechagias, StergiosBartholomä, WolfDahlström, NilsLundberg, Peter
Av organisasjonen
I samme tidsskrift
Journal of Magnetic Resonance Imaging

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 18 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 55 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf