Non-invasive monitoring of systolic blood preassure on arm utilizing photoplethysmography (PPG)
Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för medicinsk teknik, Fysiologisk mätteknik.
Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Kärlkirurgi. Östergötlands Läns Landsting, Hjärtcentrum, Thorax-kärlkliniken.
Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och vård, Anestesiologi. Östergötlands Läns Landsting, Anestesi- och operationscentrum, Anestesi- och intensivvårdskliniken VIN.
Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för medicinsk teknik, Fysiologisk mätteknik.
2000 (engelsk)Inngår i: World Congress of Medical Physics and Biomedical Engineering,2000, Springer-Verlag , 2000, s. 131-135Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Photoplethysmography (PPG) can be used to measure systolic blood pressure at the brachial artery. With a specially designed probe, positioned in the most distal position beneath a pressure cuff on the upper arm, this is possible. The distance between the light source (880 nm) and the photodetector was 20 mm. A test was performed on neuro-intensive care patients by determining blood pressure from the PPG curves, and, when it was compared with systolic blood pressure obtained from inserted indwelling arterial catheters, a correlation factor of r=0.95 was achieved. The difference between blood pressure obtained using PPG and invasive blood pressure measurement was 3.9±9.1 mmHg (mean±SD), n=19. The depth to the brachial artery was 13.9±4.1 mm (mean±SD), n=18. A digital PPG system utilising pulsating light was also developed.

sted, utgiver, år, opplag, sider
Springer-Verlag , 2000. s. 131-135
Serie
Medical and Biological Engineering and Computing, ISSN 0140-0118, E-ISSN 1741-0444 ; Volume 43, Issue 1
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-32638DOI: 10.1007/BF02345134Lokal ID: 18555OAI: oai:DiVA.org:liu-32638DiVA, id: diva2:253461
Konferanse
World Congress of Medical Physics and Biomedical Engineering, July 2000, Chicago, USA
Tilgjengelig fra: 2009-10-09 Laget: 2009-10-09 Sist oppdatert: 2018-02-20

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Laurent, ClaesJönsson, BjörnVegfors, MagnusLindberg, Lars-Göran

Søk i DiVA

Av forfatter/redaktør
Laurent, ClaesJönsson, BjörnVegfors, MagnusLindberg, Lars-Göran
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 847 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf