liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Silane-dextran chemistry on lateral flow polymer chips for immunoassays
Jönsson, C., Åmic AB, Uppsala, Sweden, Biomedical Diagnostics Institute, NCSR Building, Dublin City University, Glasnevin Dublin 9, Ireland.
Åmic AB, Uppsala, Sweden.
Rundström, G., Åmic AB, Uppsala, Sweden.
Åmic AB, Uppsala, Sweden.
Vise andre og tillknytning
2008 (engelsk)Inngår i: Lab on a Chip, ISSN 1473-0197, E-ISSN 1473-0189, Vol. 8, nr 7, s. 1191-1197Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The prognosis for patients suffering from cardiovascular and many other diseases can be substantially improved if diagnosed at an early stage. High performance diagnostic testing using disposable microfluidic chips can provide a platform for realizing this vision. Åmic AB (Uppsala, Sweden) has developed a new microfluidic test chip for sandwich immunoassays fabricated by injection molding of the cycloolefin-copolymer Zeonor™. A highly ordered array of micropillars within the fluidic chip distributes the sample solution by capillary action. Since wetting of the pillar array surface is the only driving force for liquid distribution precise control of the surface chemistry is crucial. In this work we demonstrate a novel protocol for surface hydrophilization and antibody immobilization on cycloolefin-copolymer test chips, based on direct silanisation of the thermoplastic substrate. Dextran is subsequently covalently coupled to amino groups, thus providing a coating with a low contact angle suitable for antibody immobilization. The contact angle of dextran coated chips is stable for at least two months, which enables production of large batches that can be stored for extended periods of time. We demonstrate the utility of the presented platform and surface chemistry in a C-reactive protein assay with a detection limit of 2.6 ng ml-1, a dynamic range of 102 and a coefficient of variance of 15%. © The Royal Society of Chemistry.

sted, utgiver, år, opplag, sider
2008. Vol. 8, nr 7, s. 1191-1197
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-45778DOI: 10.1039/b800297eOAI: oai:DiVA.org:liu-45778DiVA, id: diva2:266674
Tilgjengelig fra: 2009-10-11 Laget: 2009-10-11 Sist oppdatert: 2017-12-13

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Martinsson, ErikLiedberg, Bo

Søk i DiVA

Av forfatter/redaktør
Martinsson, ErikLiedberg, Bo
Av organisasjonen
I samme tidsskrift
Lab on a Chip

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 308 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf