liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Impact of digital imaging on radiation doses to the patient during X-ray examination of the urinary tract
Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiofysik. Östergötlands Läns Landsting, Kirurgi- och onkologicentrum, Radiofysikavdelningen.
2005 (engelsk)Inngår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 46, nr 6, s. 657-661Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Purpose: To compare radiation doses given to patients undergoing IVU (intravenous urography) before and after digitalization of our X-ray department. Material and Methods: IVU examinations were monitored with dose area product meters before and after the X-ray department changed to digital techniques. The first step was a change from film-screen to storage phosphor plates, while the second step involved changing to a flat panel detector. Forty-two patients were included for the film-screen situation, 69 when using the storage phosphor plates, and 70 using the flat panel detector. Results: A dose reduction from 41.8 Gycm(2) to 31.5 Gycm(2) was achieved with the first step when the film-screen system was replaced with storage phosphor plates. A further reduction to 12.1 Gycm(2) was achieved using the flat panel detector. Conclusion: The introduction of the flat panel detectors made a considerable dose reduction possible.

sted, utgiver, år, opplag, sider
2005. Vol. 46, nr 6, s. 657-661
Emneord [en]
digital radiography, dosimetry, urinary
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-46068DOI: 10.1080/02841850510021616OAI: oai:DiVA.org:liu-46068DiVA, id: diva2:266964
Tilgjengelig fra: 2009-10-11 Laget: 2009-10-11 Sist oppdatert: 2017-12-13

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Persliden, Jan

Søk i DiVA

Av forfatter/redaktør
Persliden, Jan
Av organisasjonen
I samme tidsskrift
Acta Radiologica

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 93 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf