CO2 emission consequences of energy measures in buildings
Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem.
2002 (engelsk)Inngår i: Building and Environment, ISSN 0360-1323, E-ISSN 1873-684X, Vol. 37, nr 12, s. 1421-1430Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This paper studies the way in which CO2 emission levels are affected by different measures to reduce energy consumption in a building. A case study is presented which deals with a residential building in Navestad, a suburb of the Swedish city Norrköping. The building is supplied with district heating primarily delivered from a combined heat and power (CHP) plant. Three types of energy measures are studied: extra insulation, new types of window and the introduction of a heat pump. The first perspective is the city of Norrköping, with the system boundary encompassing the residential building and the CHP plants. A second worst case scenario is then presented: a Nordic perspective in which electricity produced in coal condensing power plants is assumed to cover the marginal electricity production. With the former perspective, the measures extra insulation and new windows reduce the CO2 emissions, and with the latter both measures increase the CO2 emissions. The measures extra insulation and new windows are ranked, with respect to cost for the first perspective, using a cost reduction curve for CO2 emissions. In the paper, costs from the ExternE research project are also used. © 2002 Elsevier Science Ltd. All rights reserved.

sted, utgiver, år, opplag, sider
2002. Vol. 37, nr 12, s. 1421-1430
Emneord [en]
Buildings, CO2-reduction, Energy systems, Spare heating
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-46809DOI: 10.1016/S0360-1323(01)00114-7OAI: oai:DiVA.org:liu-46809DiVA, id: diva2:267705
Tilgjengelig fra: 2009-10-11 Laget: 2009-10-11 Sist oppdatert: 2021-09-27
Inngår i avhandling
1. Interaction between Energy Systems of Buildings and Utilities in an ever-changing Environment
Åpne denne publikasjonen i ny fane eller vindu >>Interaction between Energy Systems of Buildings and Utilities in an ever-changing Environment
2003 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

The energy system of the building is integrated in a larger energy system. The focus in this thesis is on the interface between the building and the surrounding energy system. Of special interest is how changes in the building energy system or the surrounding system affect each other and how they can interact. Depending on the decision criteria applied by the designer of the building energy system, various strategies can be used vis-a-vis the surrounding energy system. These are discussed as a background to the case studies in the appended papers. The overall objective for most of the case studies is minimisation of cost. One of the papers also deals with an environmental objective. When the Nordic electricity prices are harmonised with the European market, which has a pronounced diurnal variation in spot prices rather than a significant seasonal variation, the energy systems in the Nordic countries have to be run accordingly. This is why short time steps are used throughout the year in some of the models in order to reflect the diurnal variations in the spot price for electricity. All case studies concern buildings within a district heating network, where heat is supplied with combined heat and power plants, and boilers. Some energy conservation measures are also analysed, such as extra wall insulation and new windows. Aspects studied include how life cycle cost is affected by changes in the surrounding energy system, and how the surrounding energy system is affected when the measures on the demand side are compared with investments on the supply side. A number of techniques, for example optimisation models, are developed to analyse these situations. Finally, a suggestion is made as to how the surrounding energy system and the building energy system can interact, when jointly acting on the Nordic electricity market.

sted, utgiver, år, opplag, sider
Linköping: Linköping University, 2003. s. 86
Serie
Linköping Studies in Science and Technology. Dissertations, ISSN 0345-7524 ; 827
HSV kategori
Identifikatorer
urn:nbn:se:liu:diva-177917 (URN)9173736600 (ISBN)
Disputas
2003-06-03, Planck, Fysikhuset, Campus Valla, Linköping, 10:15
Opponent
Merknad

All or some of the the partial works included in the dissertation are not registred in DiVA and therefore not linked in this post.

Tilgjengelig fra: 2021-07-07 Laget: 2021-07-07 Sist oppdatert: 2023-03-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Rolfsman, Björn

Søk i DiVA

Av forfatter/redaktør
Rolfsman, Björn
Av organisasjonen
I samme tidsskrift
Building and Environment

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 170 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf