liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Detailed CFD modeling of EMC screen for radio base stations: A benchmark study
Antón, R., Department of TECNUN, University of Navarra, Navarra 31080, Spain.
Royal Institute of Technology, Stockholm, SE-100 44, Sweden, Deparment of Energy Technology, Stockholm SE-100 44, Sweden.
Linköpings universitet, Tekniska högskolan. Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem.
2007 (engelsk)Inngår i: IEEE transactions on components and packaging technologies, ISSN 1521-3331, E-ISSN 1557-9972, Vol. 30, nr 4, s. 754-763Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The objective of this paper is to investigate the performance of five well-known turbulence models, in order to find a model that predicts the details of the flow patterns through an electromagnetic compatibility (EMC) screen. The turbulence models investigated in the present study are five different eddy-viscosity models, the standard k-e model, the renormalization group (RNG) k-e model, the realizable k-e model, the standard k-? model, as well as the shear stress transport k-? model. A steady-state 3-D detailed model, which serves as the most accurate representation of the model, was used in order to evaluate the details of the airflow paths and pressure field. The flow was assumed to be isothermal, turbulent and incompressible. A general model that covers a considerable range of velocities and geometries was validated experimentally by wind tunnel measurements. The result shows that for most of the k-e models used with correct y+ and mesh strategy, the pressure drop and the velocity field deviation is small compared to experimental data. The k-? models overpredict the overall pressure drop. When using the RNG k-e model, the total static pressure drop predicted differs around 5%-10% and the average velocity deviation at several locations before and after the screen is around 5%. © 2007 IEEE.

sted, utgiver, år, opplag, sider
2007. Vol. 30, nr 4, s. 754-763
Emneord [en]
Electromagnetic compatibility, Electromagnetic compatibility (EMC) screen, Flow control, Flow pattern, Hot wire anemometer, Inclined flow, ke, k-?, Perforated plate, Porosity, Porous materials, Pressure drop, Renormalization group (RNG), Subrack
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-47733DOI: 10.1109/TCAPT.2007.910048OAI: oai:DiVA.org:liu-47733DiVA, id: diva2:268629
Tilgjengelig fra: 2009-10-11 Laget: 2009-10-11 Sist oppdatert: 2024-09-04

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Moshfegh, Bahram

Søk i DiVA

Av forfatter/redaktør
Moshfegh, Bahram
Av organisasjonen
I samme tidsskrift
IEEE transactions on components and packaging technologies

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 311 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf