liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Improved temporal resolution in radial k-space sampling using an hourglass filter
Linköpings universitet, Institutionen för systemteknik, Bildbehandling. Linköpings universitet, Tekniska högskolan.ORCID-id: 0000-0002-9072-2204
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet.ORCID-id: 0000-0002-6189-0807
Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiofysik. Linköpings universitet, Institutionen för medicin och hälsa, Medicinsk radiologi. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Kirurgi- och onkologicentrum, Radiofysikavdelningen. Östergötlands Läns Landsting, Bildmedicinskt centrum, Röntgenkliniken i Linköping.ORCID-id: 0000-0001-8661-2232
2009 (engelsk)Inngår i: ISMRM 17th Scientific Meeting & Exhibition, Honolulu, Hawaii, USA, 2009Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Radial sampling of k-space is known to simultaneously provide both high spatial and high temporal resolution. Recently, an optimal radial profile time order based on the Golden Ratio was presented in [1]. We have adopted and modified the idea, with a focus onhigher temporal resolution without sacrificing any image quality.

[1] Winkelmann et. al.: An optimal radial profile order based on the golden ratio for time-resolved MRI, IEEE Trans. Med. Im, Vol.26, No.1,2007.

sted, utgiver, år, opplag, sider
Honolulu, Hawaii, USA, 2009.
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-50627OAI: oai:DiVA.org:liu-50627DiVA, id: diva2:271769
Tilgjengelig fra: 2009-10-13 Laget: 2009-10-13 Sist oppdatert: 2019-06-14

Open Access i DiVA

Fulltekst mangler i DiVA

Person

Magnusson, MariaDahlqvist Leinhard, OlofBrynolfsson, PatrikLundberg, Peter

Søk i DiVA

Av forfatter/redaktør
Magnusson, MariaDahlqvist Leinhard, OlofBrynolfsson, PatrikLundberg, Peter
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 451 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf