An instrument for measuring ambient dose equivalent, H*(10)
Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Institutionen för medicin och vård, Radiofysik. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Kirurgi- och onkologicentrum, Radiofysikavdelningen.ORCID-id: 0000-0003-0209-498X
Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet.
Östergötlands Läns Landsting, Kirurgi- och onkologicentrum, Radiofysikavdelningen. Linköpings universitet, Institutionen för medicin och vård, Medicinsk radiofysik. Linköpings universitet, Hälsouniversitetet.
Vise andre og tillknytning
1996 (engelsk)Inngår i: Radiation Protection Dosimetry, ISSN 0144-8420, E-ISSN 1742-3406, Vol. 67, nr 1, s. 33-39Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The design and calibration of a small and simple instrument for measuring the ambient dose equivalent, H*(10), in photon fields is described. Comprising a thermoluminescence LiF dosemeter inside a 20 mm diameter PMMA sphere, it is capable of measuring the ambient dose equivalent with a nearly isotropic response. In the interval 0.1-100 mSv and for the energy range 30 keV to 1.25 MeV the energy response is within -31% and +15% relative to that of 137Cs gamma radiation (662 keV). In practical use, it is therefore sufficient to calibrate the instrument in a 137Cs gamma field using the corresponding conversion coefficient H*(10)/Kair taken from tabulations. The possibility of using the instrument to monitor the ambient dose equivalent for energies above 1.25 MeV is discussed and indicates that the range of applicability can be extended to 4.4 MeV with an energy response within -10% relative to 662 keV.

sted, utgiver, år, opplag, sider
1996. Vol. 67, nr 1, s. 33-39
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-51629OAI: oai:DiVA.org:liu-51629DiVA, id: diva2:276120
Tilgjengelig fra: 2009-11-10 Laget: 2009-11-10 Sist oppdatert: 2017-12-12

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Link to Article

Person

Alm Carlsson, GudrunLund, EvaPettersson, Håkan

Søk i DiVA

Av forfatter/redaktør
Alm Carlsson, GudrunLund, EvaPettersson, Håkan
Av organisasjonen
I samme tidsskrift
Radiation Protection Dosimetry

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 545 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf