liu.seSearch for publications in DiVA
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Assessing a regional building applied PV potential - Spatial and dynamic analysis of supply and load matching
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem. Linköpings universitet, Tekniska fakulteten.
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem. Linköpings universitet, Tekniska fakulteten.
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem. Linköpings universitet, Tekniska fakulteten.
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem. Linköpings universitet, Tekniska fakulteten.
2016 (engelsk)Inngår i: Renewable energy, ISSN 0960-1481, E-ISSN 1879-0682, Vol. 91, s. 261-274Artikkel i tidsskrift (Fagfellevurdert) Published
Resurstyp
Text
Abstract [en]

Electricity production by PV is growing world-wide, and grid parity of PV-electricity can be found in many countries, even in low sunlight countries, such as Sweden (at latitude 58 degrees). High installation-rate of PV-systems poses a challenge to the grid-operator. Building-integrated PV-supply potential analysis was performed for Linkoping municipality in Sweden based on GIS-data for all the buildings in the municipality. The Linkoping model provides a high spatial resolution (>180 000 buildings). The data are sorted based on azimuth and tilt, categorized in steps of 10 degrees, and then used to construct hourly power supply data. The supply data are fed into the existing electricity load-profile of Linkoping municipality. The strength and novelty of the method is that it provides the possibility of varying the installation-rate in different spatial directions to better match the load-profile. The results indicate a solar supply-rate of 19, 43 and 88% respectively if using the tilted roofs (>900 kWh/m(2) x yr), the flat-roofs optimized with tilted panels for a winter solar supply and the fully available PV-area on existing buildings (8.1 km(2)). Nevertheless, in approximately 70,1400 and >3000 h/yr, respectively, surplus-power is created, which could be used to match a future load in a wider electromobility scenario. (C) 2016 Elsevier Ltd. All rights reserved.

sted, utgiver, år, opplag, sider
PERGAMON-ELSEVIER SCIENCE LTD , 2016. Vol. 91, s. 261-274
Emneord [en]
PV system; Dynamic load matching; Load profile; Self-consumption; Spatial-time distribution; Regional PV potential
HSV kategori
Identifikatorer
URN: urn:nbn:se:liu:diva-127250DOI: 10.1016/j.renene.2016.01.084ISI: 000372382800025OAI: oai:DiVA.org:liu-127250DiVA, id: diva2:921647
Merknad

Funding Agencies|Energy Systems Program; Swedish Energy Agency; Swedish Radiation Protection Authority; Swedish Environmental Agency

Tilgjengelig fra: 2016-04-20 Laget: 2016-04-19 Sist oppdatert: 2018-03-19bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Person

Molin, AndreasRohdin, PatrikMoshfegh, Bahram

Søk i DiVA

Av forfatter/redaktør
Molin, AndreasRohdin, PatrikMoshfegh, Bahram
Av organisasjonen
I samme tidsskrift
Renewable energy

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 340 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf