liu.seSök publikationer i DiVA
Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Increasing the Efficiency of SI-Engines by Spark Advance Control and Water Injection
Linköpings universitet, Institutionen för systemteknik, Fordonssystem. Linköpings universitet, Tekniska fakulteten.ORCID-id: 0000-0001-8646-8998
1997 (Engelska)Rapport (Övrigt vetenskapligt)
Abstract [en]

By directly measuring in-cylinder parameters and adjusting the spark advance, the engine efficiency can be maximized. A feedback scheme for spark-advance control using the ionization current as sensed variable has earlier been presented. One issue is to verify that the algorithm works when the environmental conditions changes the burn rate. Humidity significantly affects the burn rate and active water injection is used to slow down the combustion giving a peak pressure position (PPP) that occurs too late. The ionization current based feedback-scheme adjusts the spark advance, and moves the PPP back to optimum. An additional result is that the engine efficiency can be increased by combining active supply of water to the combustion and the spark-advance control scheme.

Ort, förlag, år, upplaga, sidor
Linköping: Department of Electrical Engineering , 1997. , s. 12
Serie
LiTH-ISY-R, ISSN 1400-3902 ; 1939
Nyckelord [en]
Engine Control, In-cylinder pressure, ionization current, peak pressure position
Nationell ämneskategori
Elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:liu:diva-139744ISRN: LiTH-ISY-R-1939OAI: oai:DiVA.org:liu-139744DiVA, id: diva2:1131578
Tillgänglig från: 2017-08-15 Skapad: 2017-08-15 Senast uppdaterad: 2021-12-16Bibliografiskt granskad
Ingår i avhandling
1. Spark Advance Modeling and Control
Öppna denna publikation i ny flik eller fönster >>Spark Advance Modeling and Control
1999 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

The spark advance determines the efficiency of spark-ignited (SI) engines by positioning the combustion in relation to the piston motion. Today's spark-advance controllers are open loopsystems that measure parameters that effect the spark-advance setting and compensate for their effects. Several parameters influence the best spark-advance setting but it would be too expensive to measure and account for all of them. This results in a schedule that is a compromise since it has to guarantee good performance over the range of all the nonmeasured parameters. A closed-loop scheme instead measures the result of the actual spark advance and maintains an optimal spark-advance setting in the presence of disturbances. To cover this area two questions must be addressed: How to determine if the spark advance is optimal and how it can be measured? This is the scope of the present work.

One possible measurement is the in-cylinder pressure, which gives the torque, but also contains important information about the combustion. The cylinder pressure can accurately be modeled using well known single-zone thermodynamic models which include the loss mechanisms of heat transfer and crevice flows. A systematic procedure for identifying heatrelease model parameters is presented.

Three well-known combustion descriptors have been presented in the literature that relate the phasing of the pressure signal to the optimal ignition timing. A parametric study was performed showing how changes in model parameters influence the combustion descriptors at optimum ignition timing.

Another possible measurement is the ionization current that uses the spark plug as a sensor, when it is not used for ignition. This is a direct in-cylinder measurement which is rich in information about the combustion. A novel approach to spark-advance controlis presented, which uses the ionization current as a sensed variable. The feedback control scheme is closely related to schemes based on in-cylinder pressure measurements, that earlier have reported good results. A key idea in this approach is to fit a model to the measured ionization current signal, and extract information about the peak pressure position from the model parameters.

The control strategy is validated on an SI production engine, demonstrating that the spark-advance controller based on ionization current interpretation can control the peak pressure position to desired positions. A new method to increase engine efficiency is presented,by using the closed-loop spark-advance control strategy in combination with active water injection. However, the major result is that the controller maintains an optimal spark advance under various conditions and in the presence of environmental disturbances such as air humidity.

Ort, förlag, år, upplaga, sidor
Linköping: Linköping University, 1999. s. 20
Serie
Linköping Studies in Science and Technology. Dissertations, ISSN 0345-7524 ; 580
Nationell ämneskategori
Annan maskinteknik
Identifikatorer
urn:nbn:se:liu:diva-181863 (URN)9172194790 (ISBN)
Disputation
1999-05-12, ISY:s seminarierum, B-huset, Linköpings universitet, Linköping, 10:15
Tillgänglig från: 2021-12-16 Skapad: 2021-12-16 Senast uppdaterad: 2021-12-16Bibliografiskt granskad

Open Access i DiVA

Increasing the Efficiency of SI-Engines by Spark Advance Control and Water Injection(441 kB)350 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 441 kBChecksumma SHA-512
e3a3c2047bee013b4fdd2b218cdf16d4f88eec267816e31adb74affae7cb6f211714b2f2718e2e21c9df50825cf0b8c469382cdd83e2a4f0d2fa467d79980b6e
Typ fulltextMimetyp application/pdf

Person

Eriksson, Lars

Sök vidare i DiVA

Av författaren/redaktören
Eriksson, Lars
Av organisationen
FordonssystemTekniska fakulteten
Elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 350 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 288 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf