liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Editorial Material: The Application of X-Rays in Radiology: From Difficult and Dangerous to Simple and Safe in AMERICAN JOURNAL OF ROENTGENOLOGY, vol 198, issue 4, pp 754-759
Maastricht University, Netherlands.ORCID-id: 0000-0002-7104-7127
Maastricht University, Netherlands; Maastricht University, Netherlands.
Maastricht University, Netherlands; Maastricht University, Netherlands.
Maastricht University, Netherlands; Maastricht University, Netherlands.
Visa övriga samt affilieringar
2012 (Engelska)Ingår i: American Journal of Roentgenology, ISSN 0361-803X, E-ISSN 1546-3141, Vol. 198, nr 4, s. 754-759Artikel i tidskrift, Editorial material (Övrigt vetenskapligt) Published
Abstract [en]

OBJECTIVE. This article will provide an assessment of the application of x-rays in the early days of radiology, which is an excellent way to come to value the convenience and safety of modern x-ray systems. CONCLUSION. The gas tubes that were originally applied for x-ray production were very unstable because of variations in the tubes vacuum. In an effort to understand some of the problems of these tubes and the high occupational exposure that was indirectly caused by the tubes erratic behavior, we measured x-ray output rates as a function of the gas pressure inside the tube. The pressure range for the optimal production of x-rays, using an original Ruhmkorff inductor as a high-voltage generator, was found to be narrow. With the vacuum changing over time, this might explain the many photographs from the first years of radiology with operators watching their unshielded tube, either with bare eyes or with a fluoroscope, and their own hand as a test object. This practice often led to severe damage of the hands and to many early deaths due to cancer. Today, after a century of technologic development of x-ray tubes and associated equipment, the total average effective dose of workers in radiology can be close to natural background levels.

Ort, förlag, år, upplaga, sidor
AMER ROENTGEN RAY SOC , 2012. Vol. 198, nr 4, s. 754-759
Nyckelord [en]
gas x-ray tubes; history of radiology; occupational radiation exposure
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:liu:diva-141449DOI: 10.2214/AJR.11.7844ISI: 000302129000018PubMedID: 22451536OAI: oai:DiVA.org:liu-141449DiVA, id: diva2:1145802
Tillgänglig från: 2017-09-29 Skapad: 2017-09-29 Senast uppdaterad: 2017-10-09

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Sök vidare i DiVA

Av författaren/redaktören
Kemerink, MartijnKemerink, Gerrit J.
I samma tidskrift
American Journal of Roentgenology
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 71 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf