liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Fast and Fully Automatic Left Ventricular Segmentation and Tracking in Echocardiography Using Shape-Based B-Spline Explicit Active Surfaces
Katholieke University of Leuven, Belgium.
Katholieke University of Leuven, Belgium; University of Minho, Portugal; University of Minho, Portugal.
University of Lyon 1, France.
Linköpings universitet, Institutionen för medicin och hälsa, Avdelningen för kardiovaskulär medicin. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Hjärt- och Medicincentrum, Fysiologiska kliniken US.ORCID-id: 0000-0002-5716-5098
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: IEEE Transactions on Medical Imaging, ISSN 0278-0062, E-ISSN 1558-254X, Vol. 36, nr 11, s. 2287-2296Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Cardiac volume/function assessment remains a critical step in daily cardiology, and 3-D ultrasound plays an increasingly important role. Fully automatic left ventricular segmentation is, however, a challenging task due to the artifacts and low contrast-to-noise ratio of ultrasound imaging. In this paper, a fast and fully automatic framework for the full-cycle endocardial left ventricle segmentation is proposed. This approach couples the advantages of the B-spline explicit active surfaces framework, a purely image information approach, to those of statistical shape models to give prior information about the expected shape for an accurate segmentation. The segmentation is propagated throughout the heart cycle using a localized anatomical affine optical flow. It is shown that this approach not only outperforms other state-of-the-art methods in terms of distance metrics with a mean average distances of 1.81 +/- 0.59 and 1.98 +/- 0.66 mm at end-diastole and end-systole, respectively, but is computationally efficient (in average 11 s per 4-D image) and fully automatic.

Ort, förlag, år, upplaga, sidor
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC , 2017. Vol. 36, nr 11, s. 2287-2296
Nyckelord [en]
3-D echocardiography; left ventricle segmentation; B-spline explicit active surfaces; statistical shape model; localized anatomical affine optical flow
Nationell ämneskategori
Datorgrafik och datorseende
Identifikatorer
URN: urn:nbn:se:liu:diva-142967DOI: 10.1109/TMI.2017.2734959ISI: 000414134200009PubMedID: 28783626OAI: oai:DiVA.org:liu-142967DiVA, id: diva2:1156568
Anmärkning

Funding Agencies|European Research Council under the European Union [281748]; FCT Fundacao para a Ciencia e a Tecnologia, Portugal [SFRH/BD/93443/2013]

Tillgänglig från: 2017-11-13 Skapad: 2017-11-13 Senast uppdaterad: 2025-02-07

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Sök vidare i DiVA

Av författaren/redaktören
Engvall, Jan
Av organisationen
Avdelningen för kardiovaskulär medicinMedicinska fakultetenFysiologiska kliniken US
I samma tidskrift
IEEE Transactions on Medical Imaging
Datorgrafik och datorseende

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 237 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf