liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparison of ppb-level gas measurements with a metal-oxide semiconductor gas sensor in two independent laboratories
Linköpings universitet, Institutionen för fysik, kemi och biologi, Sensor- och aktuatorsystem. Linköpings universitet, Tekniska fakulteten. Saarland Univ, Germany.
Saarland Univ, Germany.
Bundesanstalt Mat Forsch and Prufung BAM, Germany.
Bundesanstalt Mat Forsch and Prufung BAM, Germany; Fraunhofer Wilhelm Klauditz Inst, Germany.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: Sensors and actuators. B, Chemical, ISSN 0925-4005, E-ISSN 1873-3077, Vol. 273, s. 1037-1046Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In this work, we use a gas sensor system consisting of a commercially available gas sensor in temperature cycled operation. It is trained with an extensive gas profile for detection and quantification of hazardous volatile organic compounds (VOC) in the ppb range independent of a varying background of other, less harmful VOCs and inorganic interfering gases like humidity or hydrogen. This training was then validated using a different gas mixture generation apparatus at an independent lab providing analytical methods as reference. While the varying background impedes selective detection of benzene and naphthalene at the low concentrations supplied, both formaldehyde and total VOC can well be quantified, after calibration transfer, by models trained with data from one system and evaluated with data from the other system. The lowest achievable root mean squared errors of prediction were 49 ppb for formaldehyde (in a concentration range of 20-200 ppb) and 150 mu g/m(3) (in a concentration range of 25-450 mu g/m(3)) for total VOC. The latter uncertainty improves to 13 mu g/m(3) with a more confined model range of 220-320 mu g/m(3). The data from the second lab indicate an interfering gas which cannot be detected analytically but strongly influences the sensor signal. This demonstrates the need to take into account all sensor relevant gases, like, e.g., hydrogen and carbon monoxide, in analytical reference measurements.

Ort, förlag, år, upplaga, sidor
ELSEVIER SCIENCE SA , 2018. Vol. 273, s. 1037-1046
Nyckelord [en]
Indoor air quality; Volatile organic compounds; Calibration transfer; Selective quantification; Inter-lab comparison
Nationell ämneskategori
Annan kemiteknik
Identifikatorer
URN: urn:nbn:se:liu:diva-150838DOI: 10.1016/j.snb.2018.06.097ISI: 000441519000130OAI: oai:DiVA.org:liu-150838DiVA, id: diva2:1245928
Anmärkning

Funding Agencies|European Union [604311]

Tillgänglig från: 2018-09-06 Skapad: 2018-09-06 Senast uppdaterad: 2018-09-06

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Bastuck, Manuel
Av organisationen
Sensor- och aktuatorsystemTekniska fakulteten
I samma tidskrift
Sensors and actuators. B, Chemical
Annan kemiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 609 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf