liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Measurement of layer-like hemodynamic trends in scalp and cortex: implications for physiological baseline suppression in functional near-infrared spectroscopy
University of Rochester, The Institute of Optics, USA.
University of Rochester, The Institute of Optics, USA.
2008 (Engelska)Ingår i: Journal of Biomedical Optics, ISSN 1083-3668, E-ISSN 1560-2281, Vol. 13, nr 3, s. 034017-1-034017-10, artikel-id 034017Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A multidetector, continuous wave, near-infrared spectroscopy (NIRS) system is developed to examine whether the hemodynamics of the scalp and brain in adults contain significant layer-like hemodynamic trends. NIRS measurements are made using contrasting geometries, one with four detectors equidistant from a source 33 mm away, and one with detectors collinear with the source (5 to 33 mm away). When NIRS time series are acquired over the prefrontal cortex from resting adults using both geometries, variations among the time series are consistent with a substantially homogeneous two-layer model (p<0.001) and inconsistent with one dominated by heterogeneities. Additionally, when time series measured 5 mm from the source are subtracted from corresponding 33-mm signals via a least-squares algorithm, 60% of the hemoglobin changes are on average removed. These results suggest that hemodynamic trends present in the scalp can contribute significantly to NIRS measurements, and that attempts to reduce this noise by subtracting a simultaneous near-channel measurement using a two-layer model are justified. Such subtractions are then performed on NIRS measurements from two stimulus protocols. For systemic stimulations (Valsalva maneuver), the subtraction cancels the hemodynamic response, as desired. For localized stimulation of the occipital lobe (viewing a flickering pattern), the subtraction isolated a stimulus-correlated hemodynamic feature from background noise.

Ort, förlag, år, upplaga, sidor
OSA Publishing , 2008. Vol. 13, nr 3, s. 034017-1-034017-10, artikel-id 034017
Nyckelord [en]
Near-infrared spectroscopy; cerebral hemodynamic; functional imaging; layer model.
Nationell ämneskategori
Fysik
Identifikatorer
URN: urn:nbn:se:liu:diva-152339DOI: 10.1117/1.2940587OAI: oai:DiVA.org:liu-152339DiVA, id: diva2:1259392
Tillgänglig från: 2018-10-29 Skapad: 2018-10-29 Senast uppdaterad: 2018-10-29Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Saager, Rolf B.

Sök vidare i DiVA

Av författaren/redaktören
Saager, Rolf B.
I samma tidskrift
Journal of Biomedical Optics
Fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 79 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf