liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Impact of hemoglobin breakdown products in the spectral analysis of burn wounds using spatial frequency domain spectroscopy
University of California Irvine, Beckman Laser Institute and Medical Clinic, Irvine, California, United States.
University of California Irvine, Beckman Laser Institute and Medical Clinic, Irvine, California, United States.
University of California Irvine, Beckman Laser Institute and Medical Clinic, Irvine, California, United States.
University of California Irvine, Beckman Laser Institute and Medical Clinic, Irvine, California, United States.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Journal of Biomedical Optics, ISSN 1083-3668, E-ISSN 1560-2281, Vol. 24, nr 2, artikel-id 020501Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Burn wounds and wound healing invoke several biological processes that may complicate the interpretation of spectral imaging data. Through analysis of spatial frequency domain spectroscopy data (450 to 1000 nm) obtained from longitudinal investigations using a graded porcine burn wound healing model, we have identified features in the absorption spectrum that appear to suggest the presence of hemoglobin breakdown products, e.g., methemoglobin. Our results show that the calculated concentrations of methemoglobin directly correlate with burn severity, 24 h after the injury. In addition, tissue parameters such as oxygenation (StO2) and water fraction may be underestimated by 20% and 78%, respectively, if methemoglobin is not included in the spectral analysis.

Ort, förlag, år, upplaga, sidor
SPIE - International Society for Optical Engineering, 2019. Vol. 24, nr 2, artikel-id 020501
Nyckelord [en]
burns; hemoglobin; methemoglobin; spectroscopy; multispectral imaging; spatial frequency domain spectroscopy
Nationell ämneskategori
Dermatologi och venereologi
Identifikatorer
URN: urn:nbn:se:liu:diva-156326DOI: 10.1117/1.JBO.24.2.020501ISI: 000463885200001PubMedID: 30724041Scopus ID: 2-s2.0-85061141061OAI: oai:DiVA.org:liu-156326DiVA, id: diva2:1304954
Tillgänglig från: 2019-04-15 Skapad: 2019-04-15 Senast uppdaterad: 2019-04-23Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Saager, Rolf B.

Sök vidare i DiVA

Av författaren/redaktören
Saager, Rolf B.
I samma tidskrift
Journal of Biomedical Optics
Dermatologi och venereologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 77 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf