liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Optimization of peak area precision of a GC-MS drug screening method using a nonparametric sign test
Swedish Natl Forens Ctr NFC, S-58194 Linkoping, Sweden.
Swedish Natl Forens Ctr NFC, S-58194 Linkoping, Sweden.
Swedish Natl Forens Ctr NFC, S-58194 Linkoping, Sweden.
Swedish Natl Forens Ctr NFC, S-58194 Linkoping, Sweden.
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Accreditation and Quality Assurance, ISSN 0949-1775, E-ISSN 1432-0517, Vol. 24, nr 3, s. 215-226Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The optimization of a number ofgas chromatography-mass spectrometry (GC-MS) parameters in order to improve peak area precision through the application of a nonparametric statistical test (the sign test) is demonstrated. As an example, the drug screening method used at the Swedish National Forensic Centre (NFC) is optimized, but in principle, any GC-MS method could be optimized using this approach. The GC-MS parameters investigated were those often overlooked in the optimization process, namely injection volume, liner type, oven temperature program, final oven temperature, MS scan range and MS scan rate. The influence of these parameters on the precision of the peak area responses of 11 different compounds in a test mixture was evaluated using the sign test for pairwise comparison. This nonparametric test provides probability values which facilitate the ranking of parameters according to their influence on peak area variation as well as providing a measure of their statistical significance. This study presents the resulting optimized method and shows that the decreased total variation depended predominantly on liner type and MS scan rate settings. This work also shows that optimization of analytical methods can be achieved using simple and easily accessible statistical tools.

Ort, förlag, år, upplaga, sidor
SPRINGER , 2019. Vol. 24, nr 3, s. 215-226
Nyckelord [en]
GC-MS; Illicit drugs; Optimization; Sign test; Precision
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:liu:diva-158316DOI: 10.1007/s00769-019-01376-wISI: 000468027000006OAI: oai:DiVA.org:liu-158316DiVA, id: diva2:1333935
Tillgänglig från: 2019-07-02 Skapad: 2019-07-02 Senast uppdaterad: 2019-07-02

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Dahlén, Johan
Av organisationen
KemiTekniska fakulteten
I samma tidskrift
Accreditation and Quality Assurance
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 117 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf