liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A comparison of stability of chemical analytes in plasma from the BD Vacutainer (R) Barricor (TM) tube with mechanical separator versus tubes containing gel separator
Linköpings universitet, Institutionen för biomedicinska och kliniska vetenskaper, Avdelningen för klinisk kemi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Diagnostikcentrum, Klinisk kemi.
Linköpings universitet, Institutionen för biomedicinska och kliniska vetenskaper, Avdelningen för klinisk kemi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Diagnostikcentrum, Klinisk kemi.
Linköpings universitet, Institutionen för biomedicinska och kliniska vetenskaper, Avdelningen för cellbiologi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Diagnostikcentrum, Klinisk kemi.
2020 (Engelska)Ingår i: Journal of clinical laboratory analysis (Print), ISSN 0887-8013, E-ISSN 1098-2825, Vol. 34, nr 2, artikel-id e23060Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: There is a need of prolonged stability of certain chemical analytes in lithium heparin tubes with separators. A new tube with a mechanical separator has recently been launched (Barricor (TM)), which according to the manufacturer may have these benefits. The aim of this study was to evaluate stability performance of this tube in comparison with plasma gel tubes under clinically realistic circumstances. Methods: Blood was collected in tubes containing lithium heparin with different separators; gel separator (Vacutainer (R) PST (TM), Becton Dickinson and Vacuette (R), Greiner bio-one) and mechanical separator (Vacutainer (R) Barricor (TM), Becton Dickinson). All tubes had an aspiration volume of 3 mL and were centrifuged at similar time and force. Tubes were transported manually or by car. Seven analytes from 122 patients were analyzed after 3 to 80 hours by Cobas c701 (Roche). Results The Barricor (TM) tube showed increased stability of phosphate and potassium and similar stability of aspartate aminotransferase, glucose, homocysteine, lactate dehydrogenase, and magnesium compared with gel tubes. Maximal allowable bias for phosphate was exceeded after 68 hours for Barricor (TM) tubes compared with 29 or 35 hours for gel tubes and for potassium after 40 hours for Barricor (TM) tubes vs 9 or 12 hours for gel tubes. Transportation did not affect stability. Hemolysis index was slightly lower in Barricor tubes than in gel tubes (P = .01). Conclusion Implementing the new Barricor (TM) tube will improve stability of potassium and phosphate in plasma. Blood sampling facilities far from the laboratory may benefit from using these tubes, thus diminishing preanalytical errors.

Ort, förlag, år, upplaga, sidor
WILEY , 2020. Vol. 34, nr 2, artikel-id e23060
Nyckelord [en]
phosphate; plasma; potassium; separator; stability; tube
Nationell ämneskategori
Läkemedelskemi
Identifikatorer
URN: urn:nbn:se:liu:diva-161391DOI: 10.1002/jcla.23060ISI: 000490068000001PubMedID: 31605419OAI: oai:DiVA.org:liu-161391DiVA, id: diva2:1367470
Tillgänglig från: 2019-11-04 Skapad: 2019-11-04 Senast uppdaterad: 2021-04-25

Open Access i DiVA

fulltext(838 kB)776 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 838 kBChecksumma SHA-512
ed3e8320be56c92b608cdcc2ae41a951af2b2385aa9027cbf1b73dcfad43f710ef2824591d479386e830771b49802621bbe2e31f42a564001b47f67031748391
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMed

Person

Landberg, Eva

Sök vidare i DiVA

Av författaren/redaktören
Gawria, GhassaanTillmar, LindaLandberg, Eva
Av organisationen
Avdelningen för klinisk kemiMedicinska fakultetenKlinisk kemiAvdelningen för cellbiologi
I samma tidskrift
Journal of clinical laboratory analysis (Print)
Läkemedelskemi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 776 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 597 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf