liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A Novel Technique to Assess Distal Radioulnar Joint Stability Using Increasing Torque
Linköpings universitet, Institutionen för klinisk och experimentell medicin. Linköpings universitet, Medicinska fakulteten.
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Maskinkonstruktion. Linköpings universitet, Tekniska fakulteten.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för Kirurgi, Ortopedi och Onkologi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Diagnostikcentrum, Medicinsk strålningsfysik.ORCID-id: 0000-0002-8387-0583
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för Kirurgi, Ortopedi och Onkologi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Sinnescentrum, Hand- och plastikkirurgiska kliniken US.ORCID-id: 0000-0002-4997-6835
2019 (Engelska)Ingår i: Journal of wrist surgery, ISSN 2163-3916, E-ISSN 2163-3924, Vol. 8, nr 4, s. 327-334Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background Previous studies on computed tomography (CT) in patients with a suspected triangular fibrocartilage complex (TFCC) injury have not been successful in assessing distal radioulnar joint (DRUJ) laxity. The aim of this study was to develop a novel servomotor-driven device for the assessment of DRUJ by applying increasing torque to the DRUJ in pronation and supination.

Methods A custom-built device was designed to function during four-dimensional (4D) CT of the wrist. A torque meter, positioned between the incoming hand holder, and a direct current (DC) servomotor were used for angular positioning and for applying rotational force to the patient's arm. A total of 110 healthy participants were recruited to gather reference values for the range of motion (ROM), maximum torque in neutral and supinated/pronated position, and the ability to withstand an increasing, device-generated torque in these positions. The device was also used during 4D DRUJ CT in five patients with suspected TFCC injuries.

Results A gender- and age-relevant reference chart for ROM and torque was created. Men showed a tendency (ns) toward having a larger ROM and increasing strength with increasing age, whereas women showed the opposite. Also, the dominant hand showed a tendency toward having a larger ROM and being stronger than the nondominant hand (ns). A smaller cohort of patients (n = 5) with suspected TFCC injuries showed a significantly decreased ability to withstand increasing torque in both supination (2.1 ± 0.3 vs. 3.1 ± 0.2 s; p < 0.005) and pronation (2.3 ± 0.5 vs. 3.1 ± 0.4 s; p < 0.0005) and also showed a clear laxity on real-time 4D CT image sequences. Decreased strength at all positions was also found (average 74% decrease compared to noninjured side).

Conclusion Reference values for torque strength and ability to withstand increasing torque can be used clinically in the assessment of patients with symptoms that could represent ligamentous injuries to the TFCC. The ability to use the device during CT enables radiographic evaluation of instability during increasing torque.

Level of Evidence This is a Level II study.

Ort, förlag, år, upplaga, sidor
Thieme Medical Publishers, 2019. Vol. 8, nr 4, s. 327-334
Nyckelord [en]
DRUJ Instability; TFCC injury; 4D CT; torque
Nationell ämneskategori
Ortopedi
Identifikatorer
URN: urn:nbn:se:liu:diva-164446DOI: 10.1055/s-0038-1675561ISI: 000484312000014PubMedID: 31402996OAI: oai:DiVA.org:liu-164446DiVA, id: diva2:1417437
Tillgänglig från: 2020-03-28 Skapad: 2020-03-28 Senast uppdaterad: 2024-01-10Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Person

Hallberg, PeterTesselaar, ErikFarnebo, Simon

Sök vidare i DiVA

Av författaren/redaktören
Nilsson, KlaraHallberg, PeterTesselaar, ErikFarnebo, Simon
Av organisationen
Institutionen för klinisk och experimentell medicinMedicinska fakultetenMaskinkonstruktionTekniska fakultetenAvdelningen för Kirurgi, Ortopedi och OnkologiMedicinsk strålningsfysikHand- och plastikkirurgiska kliniken US
I samma tidskrift
Journal of wrist surgery
Ortopedi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 227 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf