Correlation-Based Calibration for Nonlinearity Mismatches in Dual-Channel TIADCs
Natl Univ Def Technol, Peoples R China.
Natl Univ Def Technol, Peoples R China.
Linköpings universitet, Institutionen för systemteknik, Kommunikationssystem. Linköpings universitet, Tekniska fakulteten.
Natl Univ Def Technol, Peoples R China.
Visa övriga samt affilieringar
2020 (Engelska)Ingår i: IEEE Transactions on Circuits and Systems - II - Express Briefs, ISSN 1549-7747, E-ISSN 1558-3791, Vol. 67, nr 3, s. 585-589Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Mismatches affect the dynamic performance of time-interleaved analog-to-digital converters (TIADCs). Linear mismatches can be calibrated by many mature methods, but if higher performance is required, nonlinearity mismatches have to be suppressed. The background calibration method based on input-free band (IFB) functions poorly for narrow-band signals. This brief proposes a correlation-based calibration method for nonlinearity mismatches in dual-channel TIADCs which behaves well for both wide-band and narrow-band signals. The output samples are calibrated by reducing the residual distortions which are approximated by multiplying the pseudo distortions and the estimated mismatch coefficients. The pseudo distortions are acquired by using a frequency-shifter, a differentiator, and multipliers. The coefficients which indicate the mismatch strength are estimated by eliminating the cross-correlation of the calibrated output samples and the calibrated pseudo distortions at zero lag. Simulations show that the proposed method can improve the SFDR by dozens of dBc for narrow-band input signals, compared with the IFB method. For the 16-QAM signal, the error vector magnitude improvement over the IFB method is 35.48 dB.

Ort, förlag, år, upplaga, sidor
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC , 2020. Vol. 67, nr 3, s. 585-589
Nyckelord [en]
Estimation; Calibration; Nonlinear distortion; Integrated circuit modeling; Buffer storage; Time-interleaved (TI); analog-to-digital converter (ADC); nonlinearity mismatches; calibration; correlation; background estimation
Nationell ämneskategori
Reglerteknik
Identifikatorer
URN: urn:nbn:se:liu:diva-165483DOI: 10.1109/TCSII.2019.2916430ISI: 000526541600036OAI: oai:DiVA.org:liu-165483DiVA, id: diva2:1428583
Anmärkning

Funding Agencies|National Natural Science Foundation of ChinaNational Natural Science Foundation of China [61701509, 61704191]

Tillgänglig från: 2020-05-06 Skapad: 2020-05-06 Senast uppdaterad: 2020-05-06

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Johansson, Håkan
Av organisationen
KommunikationssystemTekniska fakulteten
I samma tidskrift
IEEE Transactions on Circuits and Systems - II - Express Briefs
Reglerteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 327 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf