liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Prehospital Monitoring of Vital Parameters Using a Novel Device - RespiHeart
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för Kirurgi, Ortopedi och Onkologi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Katastrofmedicinskt centrum.ORCID-id: 0000-0003-3708-1978
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för Kirurgi, Ortopedi och Onkologi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Katastrofmedicinskt centrum.ORCID-id: 0000-0003-1383-375x
2017 (Engelska)Ingår i: Prehospital and Disaster Medicine, ISSN 1049-023X, E-ISSN 1945-1938, Vol. 32, nr Suppl. 1, s. S165-S166Artikel i tidskrift, Meeting abstract (Refereegranskat) Published
Abstract [en]

Study/Objective: The study aims at validating a novel device (RespiHeart) for monitoring vital parameters in traumatically injured patients. Background: There is a need for a simple-to-use method for monitoring of vital parameters in the prehospital setting. RespiHeart is a small medical device that is attached to the sternum. It sends light of defined wavelengths into the underlying vasculature, and measures the reflected light. The resulting signals are then treated using proprietary algorithms to obtain heart rate and respiratory rate. The device has the capability to also measure oxygen saturation, temperature and movement. Methods: The device was tested during training sessions for medical personnel, where various traumatic wounds were inflicted on anesthetized pigs. The training was primarily focused on teaching acute lifesaving interventions. The RespiHeart device was applied to the animal and used to monitor vital parameters throughout the training session. A total of 22 animals were included in the study. The data gathered from Respiheart were compared to results from a pulse oximeter and ventilator connected to the animal. Statistical comparison were performed using linear regression and Bland-Altman plots to analyze agreement of methods. Results: The heart rate as measured by the pulse oximeter was correlated to the rate reported by RespiHeart. The R2 was 0.9946 with a p-value of less than 0.0001. Bland-Altman analysis of heart rate revealed a bias of -0.06127 (95% CI -2.219- 2.097). The respiratory rate as set on the ventilator was correlated to the rate reported by RespiHeart. The R2 was 0.9978 with a p-value of less than 0.0001. Bland-Altman analysis of respiratory rate revealed a bias of -0.008584 (95% CI -0.42-0.4028). Conclusion: The results obtained in this study demonstrate a high degree of correlation between the data obtained from RespiHeart and the pulse oximeter and ventilator. This renders RespiHeart as a promising device for prehospital use.

Ort, förlag, år, upplaga, sidor
Cambridge University Press, 2017. Vol. 32, nr Suppl. 1, s. S165-S166
Nationell ämneskategori
Anestesi och intensivvård Medicinsk instrumentering
Identifikatorer
URN: urn:nbn:se:liu:diva-169698DOI: 10.1017/S1049023X17004460OAI: oai:DiVA.org:liu-169698DiVA, id: diva2:1468053
Konferens
WADEM Congress on Disaster and Emergency Medicine 2017
Tillgänglig från: 2020-09-16 Skapad: 2020-09-16 Senast uppdaterad: 2025-02-10Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Junker, JohanJonson, Carl-Oscar

Sök vidare i DiVA

Av författaren/redaktören
Junker, JohanJonson, Carl-Oscar
Av organisationen
Avdelningen för Kirurgi, Ortopedi och OnkologiMedicinska fakultetenKatastrofmedicinskt centrum
I samma tidskrift
Prehospital and Disaster Medicine
Anestesi och intensivvårdMedicinsk instrumentering

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 261 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf