liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
High Correlation between Ethanol Concentrations in Postmortem Femoral Blood and in Alternative Biological Specimens but Large Uncertainty When the Linear Regression Model Was Used for Prediction in Individual Cases
Natl Board Forens Med, Dept Forens Genet & Forens Toxicol, SE-58758 Linkoping, Sweden.
Linköpings universitet, Institutionen för biomedicinska och kliniska vetenskaper, Avdelningen för läkemedelsforskning. Linköpings universitet, Medicinska fakulteten. Natl Board Forens Med, Dept Forens Genet & Forens Toxicol, SE-58758 Linkoping, Sweden.
Linköpings universitet, Institutionen för biomedicinska och kliniska vetenskaper, Avdelningen för läkemedelsforskning. Linköpings universitet, Medicinska fakulteten.
2020 (Engelska)Ingår i: Journal of Analytical Toxicology, ISSN 0146-4760, E-ISSN 1945-2403, Vol. 44, nr 5, s. 415-421Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In connection with medicolegal autopsies peripheral blood (e.g. from a femoral vein) is the specimen of choice for toxicological analysis, although alternative specimens are also sometimes submitted, such as bile, cerebrospinal fluid (CSF), vitreous humor (VH), bladder urine, pleural effusions and/or lung fluid. Ethanol concentrations were determined in duplicate in femoral blood and in various alternative biological specimens by headspace gas chromatography. The analysis was carried out on two different fused silica capillary columns furnishing different retention times for ethanol and both n-propanol and t-butanol were used as internal standards. The results were evaluated by linear regression using blood alcohol concentration (BAC) as dependent or outcome variable and the concentrations in an alternative specimen as independent or predictor variable. The Pearson correlation coefficients were all statistically highly significant (P < 0.001); r = 0.94 (bile), r = 0.98 (CSF), r = 0.97 (VH), r = 0.92 (urine), r = 0.94 (lung fluid) and r = 0.96 (pleural cavity effusions). When the regression model was used to predict femoral BAC from the mean concentration in an alternative specimen the mean and 95% prediction intervals were 1.12 +/- 0.824 g/L (bile), 1.41 +/- 0.546 g/L (CSF), 1.15 +/- 0.42 g/L (VH), 1.29 +/- 0.780 g/L (urine), 1.25 +/- 0.772 g/L (lung fluid) and 0.68 +/- 0.564 g/L (pleural cavity effusions). This large uncertainty for a single new observation needs to be considered when alcohol-related deaths are evaluated and interpreted. However, the analysis of alternative specimens is recommended in medical examiner cases to provide supporting evidence with regard to the origin of ethanol, whether this reflects antemortem (AM) ingestion or postmortem (PM) synthesis.

Ort, förlag, år, upplaga, sidor
OXFORD UNIV PRESS INC , 2020. Vol. 44, nr 5, s. 415-421
Nationell ämneskategori
Arbetsmedicin och miljömedicin
Identifikatorer
URN: urn:nbn:se:liu:diva-173211DOI: 10.1093/jat/bkaa018ISI: 000607117200001PubMedID: 32104897OAI: oai:DiVA.org:liu-173211DiVA, id: diva2:1527387
Tillgänglig från: 2021-02-10 Skapad: 2021-02-10 Senast uppdaterad: 2021-02-10

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Sök vidare i DiVA

Av författaren/redaktören
Kugelberg, FredrikJones, A Wayne
Av organisationen
Avdelningen för läkemedelsforskningMedicinska fakulteten
I samma tidskrift
Journal of Analytical Toxicology
Arbetsmedicin och miljömedicin

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 36 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf