liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A Novel Approach to Hematology Testing at the Point of Care
PixCell Med Technol Ltd, Israel.
Uppsala Univ, Sweden.
Linköpings universitet, Institutionen för biomedicinska och kliniska vetenskaper, Avdelningen för klinisk kemi och farmakologi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Diagnostikcentrum, Klinisk kemi.
PixCell Med Technol Ltd, Israel.
Visa övriga samt affilieringar
2021 (Engelska)Ingår i: The Journal of Applied Laboratory Medicine, ISSN 2576-9456, E-ISSN 2475-7241, Vol. 6, nr 2, s. 532-542Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: The need for rapid point-of-care (POC) diagnostics is now becoming more evident due to the increasing need for timely results and improvement in healthcare service. With the recent COVID-19 pandemic outbreak, POC has become critical in managing the spread of disease. Applicable diagnostics should be readily deployable, easy to use, portable, and accurate so that they fit mobile laboratories, pop-up treatment centers, field hospitals, secluded wards within hospitals, or remote regions, and can be operated by staff with minimal training. Complete blood count (CBC), however, has not been available at the POC in a simple-to-use device until recently. The HemoScreen, which was recently cleared by the FDA for POC use, is a miniature, easy-to-use instrument that uses disposable cartridges and may fill this gap. Content: The HemoScreens analysis method, in contrast to standard laboratory analyzers, is based on machine vision (image-based analysis) and artificial intelligence (AI). We discuss the different methods currently used and compare their results to the vision-based one. The HemoScreen is found to correlate well to laser and impedance-based methods while emphasis is given to mean cell volume (MCV), mean cell hemoglobin (MCH), and platelets (PLT) that demonstrate better correlation when the vision-based method is compared to itself due to the essential differences between the underlying technologies. Summary: The HemoScreen analyzer demonstrates lab equivalent performance, tested at different clinical settings and sample characteristics, and might outperform standard techniques in the presence of certain interferences. This new approach to hematology testing has great potential to improve quality of care in a variety of settings.

Ort, förlag, år, upplaga, sidor
OXFORD UNIV PRESS INC , 2021. Vol. 6, nr 2, s. 532-542
Nationell ämneskategori
Medicinsk laboratorieteknik
Identifikatorer
URN: urn:nbn:se:liu:diva-174649DOI: 10.1093/jalm/jfaa186ISI: 000625293300023PubMedID: 33274357Scopus ID: 2-s2.0-85102657359OAI: oai:DiVA.org:liu-174649DiVA, id: diva2:1541545
Tillgänglig från: 2021-04-01 Skapad: 2021-04-01 Senast uppdaterad: 2025-11-04Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Aardal-Eriksson, Elisabeth

Sök vidare i DiVA

Av författaren/redaktören
Aardal-Eriksson, Elisabeth
Av organisationen
Avdelningen för klinisk kemi och farmakologiMedicinska fakultetenKlinisk kemi
I samma tidskrift
The Journal of Applied Laboratory Medicine
Medicinsk laboratorieteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 309 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf