liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A multivalent aptamer-based electrochemical biosensor for biomarker detection in urinary tract infection
Denmark Tech Univ, Denmark.
Linköpings universitet, Institutionen för teknik och naturvetenskap, Laboratoriet för organisk elektronik. Linköpings universitet, Tekniska fakulteten.ORCID-id: 0000-0003-3606-3532
Denmark Tech Univ, Denmark.
Int Iberian Nanotechnol Lab INL, Portugal.
Visa övriga samt affilieringar
2021 (Engelska)Ingår i: Electrochimica Acta, ISSN 0013-4686, E-ISSN 1873-3859, Vol. 389, artikel-id 138644Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Lactoferrin is a multifunctional protein of the transferrin family and is known as a biomarker for various clinical diseases including urinary tract infection (UTI). However, wide concentration range of lactoferrin in urine samples due to the high interpatient variations, requires a more practical biosensor. In this article, we used a novel multivalent aptamer immobilized on the surface of screen-printed gold electrode (aptamer/SPGE) to develop the first electrochemical aptasensor for label-free detection of lactoferrin with wide dynamic detection range and high sensitivity. The performance of the fabricated biosensor was tested using electrochemical impedance spectroscopy and differential pulse voltammetry. The multivalent aptamer as the bioreceptor with high affinity and good specificity against human lactoferrin, acts to enhance the electrochemical signals and widen the working window. The aptamer/SPGE demonstrates superior sensing performances for lactoferrin in buffer solution, with a wide linear range of 10 to 1300 ng/mL with LOD of 0.9 ng/mL, as well as high selectivity, and excellent reproducibility. Besides, the constructed aptasensor was successfully applied to quantify lactoferrin concentrations in spiked urine solutions. Owing to excellent sensitivity, ease of miniaturization, simple sensing procedure, low-cost, and fast response, the proposed electrochemical aptasensor indicates a great potential towards the development of lactoferrin analysis systems, which would be helpful in the early diagnosis of UTI. (C) 2021 Elsevier Ltd. All rights reserved.

Ort, förlag, år, upplaga, sidor
PERGAMON-ELSEVIER SCIENCE LTD , 2021. Vol. 389, artikel-id 138644
Nyckelord [en]
Aptamer; Electrochemical biosensor; Lactoferrin; Screen-printed gold electrode; Urinary tract infection
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:liu:diva-183937DOI: 10.1016/j.electacta.2021.138644ISI: 000766530200008OAI: oai:DiVA.org:liu-183937DiVA, id: diva2:1648981
Anmärkning

Funding Agencies|Innovation Fund Denmark [8127-0 0 021B, 0 0 022912]; Marie Curie Co-Fund Action [713640]; NanoTRAINforGrowthII-INL Fellowship program in nanotechnologies for nanomedicine, energy, ICT, food and environment applications

Tillgänglig från: 2022-04-01 Skapad: 2022-04-01 Senast uppdaterad: 2023-12-28

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Halder, Arnab
Av organisationen
Laboratoriet för organisk elektronikTekniska fakulteten
I samma tidskrift
Electrochimica Acta
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 36 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf