liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Silicon carbide field-effect devices studied as gas sensors for exhaust gas monitoring
Linköpings universitet, Institutionen för fysik och mätteknik. Linköpings universitet, Tekniska högskolan.
1999 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Metal-insulator-silicon carbide (MIS) structures have been studied as gas sensors. We have investigated how the sensors detect gases, how fast they do that, and how they could be used for exhaust gas monitoring.

We have prepared simple field-effect devices, MIS-capacitors and Schottky diodes, on silicon carbide with platinum gates. We have tested the gas sensitivity by measuring the electrical characteristics of the devices in oxygen and in hydrogen and sometimes carbon monoxide (representing oxidising and reducing gases). The flat-band voltage of a MIS-capacitor is more positive in oxygen than in hydrogen. Hydrogen or carbon monoxide changes the current-voltage characteristics of a Schottky diode on n-type SiC in a way typical for a lowering of the barrier height. For Schottky diodes on p-type SiC, the apparent barrier height increases in hydrogen. We have determined values of barrier heights for different platinum-insulator combinations, but they differ from each other depending on the measurement method used. We conclude that the thermionic emission model does not describe the MISiC sensors well. In the introductory chapters, a mechanism is discussed how gas exposure might change the electrical characteristics of Schottky diodes and capacitors.

When we expose a MIS capacitor to hydrogen, not only the field effect influences the properties of silicon carbide. At temperatures above 600°C, the inversion capacitance of an n-type MIS capacitor decreases with increasing hydrogen pressure. We have measured and analysed the effectfor 6H and 4H n-type silicon carbide. We have suggested that the influence of hydrogen is due to a decreased minority-carrier generation in the semiconductor. For p-type material, the capacitors apparently do not build up an inversion layer.

We have studied sensor signals also in more complex gas mixtures. We have measured the effects of compounds of synthetic exhaust gas systematically using an experimental design. For each sensor temperature, we could identify one gas compound that influences the sensor signal most. To understand the origin of these effects, we have studied more closely a mixture of oxygen and carbon monoxide. We could explain the sensor behaviour qualitatively with the relative sizes of reaction kinetics and mass transport. For a medium temperature, e.g.400 °C, and high nominal gas concentrations, the oxidation of carbon monoxide is kinetically controlled: The sensor surface is covered with carbon monoxide even if oxygen is in excess, because carbon monoxide has a higher sticking coefficient on platinum. At a high temperature, e.g.500 °C, the oxidation on the platinum is very efficient. Only the gas inexcess is present on the sensor surface and dominates the sensor signal. The possibility is discussed to use an sensor array for the multicomponent analysis in exhaust gases, e.g. for the diagnosis of a catalytic converter. Not alone the sensor temperature determines the selectivity of the sensor but also the presence of reactive surfaces close to the sensor, which change the local gas concentrations.

We have investigated the response times of some MISiC sensors to see if they can be used as fast binary A-sensors for cylinder-specific monitoring of a car engine. We have invented a new method for measuring response times of fast gas sensors in the laboratory, i.e. the moving gas outlets. At temperatures of 650°C and higher, the MISiC sensors react to a change in the ambient in less than three milliseconds. Measurements in the exhaust of a bench engine have confirmed this finding.

Ort, förlag, år, upplaga, sidor
Linköping: Linköping University , 1999. , s. 87
Serie
Linköping Studies in Science and Technology. Dissertations, ISSN 0345-7524 ; 585
Nyckelord [en]
silicon carbide, high temperature, gas sensors, field effect devices, MISdevices, Schottky diodes, experimental design, reaction kinetics, mass transport, car exhaust, multipoint injection, response times, cylinder specific, on-board diagnosis
Nationell ämneskategori
Annan kemiteknik
Identifikatorer
URN: urn:nbn:se:liu:diva-184778Libris ID: 7624323ISBN: 9172194928 (tryckt)OAI: oai:DiVA.org:liu-184778DiVA, id: diva2:1656050
Disputation
1999-05-21, hörsal C3, C-huset, Linköpings universitet, Linköping, 10:15
Opponent
Anmärkning

All or some of the partial works included in the dissertation are not registered in DIVA and therefore not linked in this post.

Tillgänglig från: 2022-05-04 Skapad: 2022-05-04 Senast uppdaterad: 2022-05-13Bibliografiskt granskad
Delarbeten
1. Fast chemical sensing with metal-insulator silicon carbide structures
Öppna denna publikation i ny flik eller fönster >>Fast chemical sensing with metal-insulator silicon carbide structures
Visa övriga...
1997 (Engelska)Ingår i: IEEE Electron Device Letters, ISSN 0741-3106, E-ISSN 1558-0563, Vol. 18, nr 6, s. 287-289Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

It is demonstrated that the current-voltage characteristics of platinum-thin insulator silicon carbide diodes react rapidly to changes of the concentration of oxygen and hydrocarbons in the ambient already at temperatures around 500 degrees C-600 degrees C, In this letter, we use moving gas outlets to, for the first time, estimate time constants of the response in the order of a few milliseconds. The short time constants of these sensors make them suitable for applications in combustion monitoring. The new method to modulate gas concentrations rapidly at surfaces has the potential to be a valuable tool for evaluation of device structures for fast chemical sensing.

Ort, förlag, år, upplaga, sidor
Institute of Electrical and Electronics Engineers (IEEE), 1997
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
urn:nbn:se:liu:diva-88139 (URN)10.1109/55.585361 (DOI)A1997XA74300016 ()
Tillgänglig från: 2013-02-04 Skapad: 2013-01-30 Senast uppdaterad: 2022-05-04
2. Electrical characterization of chemical sensors based on catalytic metal gate - Silicon carbide Schottky diodes
Öppna denna publikation i ny flik eller fönster >>Electrical characterization of chemical sensors based on catalytic metal gate - Silicon carbide Schottky diodes
Visa övriga...
1998 (Engelska)Ingår i: Silicon Carbide, III-Nitrides and Related Materials, Part 1-2, Trans Tech Publications , 1998, Vol. 264-2, s. 1097-1100Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

The IV-characteristics of platinum gate Schottky diodes with an interfacial layer of TaSix or Ta depends on gas ambient and they are therefore used as gas sensors, e.g. for combustion engine monitoring. Ideality factors and barrier heights depend on interfacial layers and temperature and are further investigated here. Gas sensitive Schottky diodes on both p-and n-type SIC are shown.

Ort, förlag, år, upplaga, sidor
Trans Tech Publications, 1998
Serie
Materials Science Forum, ISSN 0255-5476 ; 264-2
Nyckelord
Schottky diodes; gas sensors; barrier height; ideality factor; interfacial layer
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
urn:nbn:se:liu:diva-88128 (URN)10.4028/www.scientific.net/MSF.264-268.1097 (DOI)000072751000262 ()0-87849-790-0 (ISBN)
Konferens
7th International Conference on Silicon Carbide, III-Nitrides and Related Materials (ICSCIII-N 97), 31 August - 5 September 1997, Stockholm, Sweden
Tillgänglig från: 2013-01-30 Skapad: 2013-01-30 Senast uppdaterad: 2022-05-04
3. Studies of the ambient dependent inversion capacitance of catalytic metal oxide silicon carbide devices based on 6H- and 4H-SiC material
Öppna denna publikation i ny flik eller fönster >>Studies of the ambient dependent inversion capacitance of catalytic metal oxide silicon carbide devices based on 6H- and 4H-SiC material
Visa övriga...
1998 (Engelska)Ingår i: Silicon Carbide, III-Nitrides and Related Materials, Part 1-2, Trans Tech Publications , 1998, Vol. 264-2, s. 1089-1092Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Platinum-oxide-silicon carbide structures change their capacitance upon gas exposure and are used as gas sensors. The decrease of the inversion capacitance within 750 to 900 degrees C due to hydrogen exposure is studied for 4H- and 6H-SiC,:both n- and p-type. A mechanism for the capacitance decrease is suggested which explains also the large change in the conductance of the structures.

Ort, förlag, år, upplaga, sidor
Trans Tech Publications, 1998
Serie
Materials Science Forum, ISSN 0255-5476 ; 264-2
Nyckelord
MIS-devices; electric admittance; high temperature; gas sensors; minority carriers
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
urn:nbn:se:liu:diva-88127 (URN)000072751000260 ()0-87849-790-0 (ISBN)
Konferens
International Conference on Silicon Carbide, III-Nitrides and Related Materials (ICSCIII-N 97), 31 August - 5 September 1997, Stockholm, Sweden
Tillgänglig från: 2013-01-30 Skapad: 2013-01-30 Senast uppdaterad: 2022-05-04
4. Response of metal-insulator-silicon carbide sensors to different components in exhaust gases
Öppna denna publikation i ny flik eller fönster >>Response of metal-insulator-silicon carbide sensors to different components in exhaust gases
Visa övriga...
1998 (Engelska)Ingår i: Sensors and actuators. B, Chemical, ISSN 0925-4005, E-ISSN 1873-3077, Vol. 47, nr 1-3, s. 125-130Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The effects of different components in simulated car exhaust gases on silicon carbide based field effect sensors are studied using a two-level factorial design. Strong effects are observed for H-2, hydrocarbons, and CO. The effects vary with temperature and can possibly be used for a multi-component analysis of exhaust gases.

Ort, förlag, år, upplaga, sidor
Elsevier, 1998
Nyckelord
gas sensors; silicon carbide; high temperatures; factorial design; car exhaust; field effect devices
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
urn:nbn:se:liu:diva-88124 (URN)10.1016/S0925-4005(98)00034-3 (DOI)000074516400020 ()
Tillgänglig från: 2013-01-30 Skapad: 2013-01-30 Senast uppdaterad: 2022-05-04Bibliografiskt granskad
5. Moving gas outlets for the evaluation of fast gas sensors
Öppna denna publikation i ny flik eller fönster >>Moving gas outlets for the evaluation of fast gas sensors
Visa övriga...
1999 (Engelska)Ingår i: Sensors and actuators. B, Chemical, ISSN 0925-4005, E-ISSN 1873-3077, Vol. 58, nr 1-3, s. 389-393Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A new method for the evaluation of fast gas sensors is described. By using moving gas outlets, we can quickly change the ambient around a sensor. Different platinum-insulator-silicon carbide (MISiC) structures are investigated. Their sensor response contains fast components, which respond within milliseconds to a change in the ambient from a reducing gas to an oxidising gas and vice versa. Cylinder specific monitoring of car engines with the MISiC structures is discussed.

Ort, förlag, år, upplaga, sidor
Elsevier, 1999
Nyckelord
gas sensors; automotive electronics; flow; silicon carbide; high temperature; MIS devices
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
urn:nbn:se:liu:diva-88114 (URN)10.1016/S0925-4005(99)00120-3 (DOI)000083579800018 ()
Tillgänglig från: 2013-01-30 Skapad: 2013-01-30 Senast uppdaterad: 2022-05-04Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Sök vidare i DiVA

Av författaren/redaktören
Tobias, Peter
Av organisationen
Institutionen för fysik och mätteknikTekniska högskolan
Annan kemiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 90 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf