liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Affinity biosensors with porous and multi-array surfaces
Linköpings universitet, Institutionen för fysik och mätteknik. Linköpings universitet, Tekniska högskolan.
1999 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Affinity biosensing is one of many analytical techniques that have high potential for the detection of drug leads. In this thesis the use of ellipsometry, surface plasmon resonance (SPR) as well as quartz crystal microbalance (QCM) as screening methods in drug discovery are presented. In particularly, attention was given to the sensing surfaces and their incorporation in multi-sensor arrays, or biochips, for monitoring the specific affinity binding of low molecular weight molecules.

Silicon dioxide and gold surfaces were rendered porous and used as the biosensing surface. Porous surfaces enhanced the performance of the biosensor considerably, due to the increase in the capacity of binding ligands. In the case of porous silicon dioxide the increase in the response is 10-fold, while porous gold showed a 6-fold increase, when employing ellipsometric measurements. It was also shown that porous gold can successfully be incorporated in SPR systems when used as a biosensor, resulting in a small increase in sensitivity when employing rough gold surface and an 20-fold increase in case of thick porous gold layers, compared to planar surfaces. The surface area of the gold electrode on the crystals was increased by rendering the electrodes porous. This increased the response up to a factor 3. Thus, porous surfaces together with ellipsometry, SPR or QCM have the advantage of not requiring labelling, such as fluorescence, isotope or antigen tags, for achieving the necessary sensitivity.

Further, ellipsometric and SPR imaging systems were introduced employing a 1 cm2 surface, containing 900 targets. These biochips are a step towards a faster highthroughput screening process. Two methods of fabrication of these biochips are shown: one based on wet etching of a silicon surface and the other on the preparation of so called tension wells on the silicon surface.

Affinity models were used throughout this work.Streptavidin was immobilised to the porous silicon to bind biotin and an oligopeptide, synthesised by means of combinatorial chemistry monitored with the ellipsometer. A protein model system consisting of anti-human myoglobin as analyte and sheep skeletal myoglobin as ligand was used in different concentrations. Measurements on the biochips were performed with carbohydrate model substances selected for six common lectins.

Ort, förlag, år, upplaga, sidor
Linköping: Linköping University , 1999. , s. 30
Serie
Linköping Studies in Science and Technology. Dissertations, ISSN 0345-7524 ; 609
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:liu:diva-185134Libris ID: 7624430ISBN: 9172196181 (tryckt)OAI: oai:DiVA.org:liu-185134DiVA, id: diva2:1666109
Disputation
1999-11-30, Planck, Fysikhuset, Linköpings universitet, Linköping, 10:15
Opponent
Anmärkning

All or some of the partial works included in the dissertation are not registered in DIVA and therefore not linked in this post.

Tillgänglig från: 2022-06-08 Skapad: 2022-06-08 Senast uppdaterad: 2022-06-08Bibliografiskt granskad
Delarbeten
1. Porous gold surfaces for biosensor applications
Öppna denna publikation i ny flik eller fönster >>Porous gold surfaces for biosensor applications
2000 (Engelska)Ingår i: Biosensors & bioelectronics, ISSN 0956-5663, E-ISSN 1873-4235, Vol. 15, nr 3-4, s. 203-209Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The sensitivity of optical biosensors where the detection takes place on a planar gold surface can be improved by making the surface porous. The porosity allows a larger number of ligands per surface area resulting in larger optical shifts when interacting with specifically binding analyte molecules. The porous gold was deposited as a thin layer on a planar gold surface by electrochemical deposition in a solution of tetrachloroaurate and lead acetate. A protein, streptavidin, was adsorbed into the formed porous layer and the time course of the adsorption was monitored by in-situ ellipsometry. When the porous layer was 500 nm in thickness a six-fold increase of the ellipsometric response was obtained compared with a planar gold surface. The dependency of porosity and layer thickness was explained with a mathematical model of the gold/porous gold/protein/solution system. Copyright (C) 2000 Elsevier Science S.A.The sensitivity of optical biosensors where the detection takes place on a planar gold surface can be improved by making the surface porous. The porosity allows a larger number of ligands per surface area resulting in larger optical shifts when interacting with specifically binding analyte molecules. The porous gold was deposited as a thin layer on a planar gold surface by electrochemical deposition in a solution of tetrachloroaurate and lead acetate. A protein, streptavidin, was adsorbed into the formed porous layer and the time course of the adsorption was monitored by in-situ ellipsometry. When the porous layer was 500 nm in thickness a six-fold increase of the ellipsometric response was obtained compared with a planar gold surface. The dependency of porosity and layer thickness was explained with a mathematical model of the gold/porous gold/protein/solution system.

Nationell ämneskategori
Naturvetenskap
Identifikatorer
urn:nbn:se:liu:diva-44230 (URN)10.1016/S0956-5663(00)00061-0 (DOI)76090 (Lokalt ID)76090 (Arkivnummer)76090 (OAI)
Tillgänglig från: 2009-10-10 Skapad: 2009-10-10 Senast uppdaterad: 2022-06-08
2. Improving the sensitivity of a quartz crystal microbalance for biosensing by using porous gold
Öppna denna publikation i ny flik eller fönster >>Improving the sensitivity of a quartz crystal microbalance for biosensing by using porous gold
2001 (Engelska)Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A quartz crystal microbalance can be used as a biosensor if biological receptor molecules (ligands) are attached to the crystal. To improve the sensitivity, the surface area of the gold electrodes on the crystal was increased by rendering the electrodes porous. This increased the response up to a factor of 3. A protein model system with human anti-myoglobin as ligand and sheep skeletal myoglobin at different concentrations as analyte was used. The quartz crystal was mounted in a flow-cell, where immobilisation, binding and regeneration of the surface were carried out. The kinetics of the model system was monitored under various experimental conditions.

Nationell ämneskategori
Naturvetenskap
Identifikatorer
urn:nbn:se:liu:diva-43744 (URN)10.1007/s006040170066 (DOI)74651 (Lokalt ID)74651 (Arkivnummer)74651 (OAI)
Tillgänglig från: 2009-10-10 Skapad: 2009-10-10 Senast uppdaterad: 2022-06-08
3. Silicon based affinity biochips viewed with imaging ellipsometry
Öppna denna publikation i ny flik eller fönster >>Silicon based affinity biochips viewed with imaging ellipsometry
2000 (Engelska)Ingår i: Measurement science and technology, ISSN 0957-0233, E-ISSN 1361-6501, Vol. 11, nr 6, s. 801-Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In this paper we report on the fabrication of an affinity biochip with a matrix of 900 targets for detection with imaging ellipsometry. Two methods of fabrication of chips are shown: one based on wet etching of a silicon surface and the other on the preparation of so-called tension wells on the silicon surface. The dispensing of reagents and ligands was performed using a pipetting robot equipped with a micro-capillary, a syringe pump and micro-stepping motors. Measurements were performed on the chips in real time with carbohydrate model substances selected for six common lectins. Affinity binding was shown for three of the tested model substances.

Nyckelord
affinity biochip, imaging ellipsometry, silicon
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
urn:nbn:se:liu:diva-60385 (URN)10.1088/0957-0233/11/6/325 (DOI)
Tillgänglig från: 2010-10-12 Skapad: 2010-10-12 Senast uppdaterad: 2022-06-08

Open Access i DiVA

Fulltext saknas i DiVA

Person

van Noort, Danny

Sök vidare i DiVA

Av författaren/redaktören
van Noort, Danny
Av organisationen
Institutionen för fysik och mätteknikTekniska högskolan
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 124 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf