Dosimetric impact of a robust optimization approach to mitigate effects from rotational uncertainty in prostate intensity‐modulated brachytherapy
Linköpings universitet, Matematiska institutionen, Tillämpad matematik. Linköpings universitet, Tekniska fakulteten.ORCID-id: 0000-0001-7191-5206
McGill Univ, Canada.
McGill Univ, Canada; Ctr Hosp Univ Montreal, Canada.
McGill Univ, Canada.
Visa övriga samt affilieringar
2023 (Engelska)Ingår i: Medical Physics, ISSN 0094-2405, E-ISSN 2473-4209, Vol. 50, nr 2, s. 1029-1043Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

BackgroundIntensity-modulated brachytherapy (IMBT) is an emerging technology for cancer treatment, in which radiation sources are shielded to shape the dose distribution. The rotatable shields provide an additional degree of freedom, but also introduce an additional, directional, type of uncertainty, compared to conventional high-dose-rate brachytherapy (HDR BT). PurposeWe propose and evaluate a robust optimization approach to mitigate the effects of rotational uncertainty in the shields with respect to planning criteria. MethodsA previously suggested prototype for platinum-shielded prostate Yb-169-based dynamic IMBT is considered. We study a retrospective patient data set (anatomical contours and catheter placement) from two clinics, consisting of six patients that had previously undergone conventional Ir-192 HDR BT treatment. The Monte Carlo-based treatment planning software RapidBrachyMCTPS is used for dose calculations. In our computational experiments, we investigate systematic rotational shield errors of +/- 10 degrees and +/- 20 degrees, and the same systematic error is applied to all dwell positions in each scenario. This gives us three scenarios, one nominal and two with errors. The robust optimization approach finds a compromise between the average and worst-case scenario outcomes. ResultsWe compare dose plans obtained from standard models and their robust counterparts. With dwell times obtained from a linear penalty model (LPM), for 10 degrees errors, the dose to urethra (D0.1cc) and rectum (D0.1cc and D1cc) increase with up to 5% and 7%, respectively, in the worst-case scenario, while with the robust counterpart, the corresponding increases were 3% and 3%. For all patients and all evaluated criteria, the worst-case scenario outcome with the robust approach had lower deviation compared to the standard model, without compromising target coverage. We also evaluated shield errors up to 20 degrees and while the deviations increased to a large extent with the standard models, the robust models were capable of handling even such large errors. ConclusionsWe conclude that robust optimization can be used to mitigate the effects from rotational uncertainty and to ensure the treatment plan quality of IMBT.

Ort, förlag, år, upplaga, sidor
WILEY , 2023. Vol. 50, nr 2, s. 1029-1043
Nyckelord [en]
high dose-rate brachytherapy; inverse treatment planning; prostate IMBT; robust optimization
Nationell ämneskategori
Annan matematik Cancer och onkologi
Identifikatorer
URN: urn:nbn:se:liu:diva-190890DOI: 10.1002/mp.16134ISI: 000905521500001PubMedID: 36478226Scopus ID: 2-s2.0-85145268798OAI: oai:DiVA.org:liu-190890DiVA, id: diva2:1729534
Forskningsfinansiär
Vetenskapsrådet, VR‐NT 2019‐05416Cancerfonden, CAN 2017/1029Cancerfonden, Pj 211788
Anmärkning

Funding: Vetenskapsradet [VR-NT 2019-05416]; Cancerfonden [CAN 2017/1029]; Canada Research Chairs [252135]; Collaborative health research projects [523394-18]

Tillgänglig från: 2023-01-20 Skapad: 2023-01-20 Senast uppdaterad: 2025-09-30Bibliografiskt granskad

Open Access i DiVA

fulltext(2122 kB)420 nedladdningar
Filinformation
Filnamn FULLTEXT02.pdfFilstorlek 2122 kBChecksumma SHA-512
e3b26adcc1af09b695fb330c494ae9351a2e478a3596a0d2c2842918b03015878e4f694466a07a5c44c61a68957fc6493ef85a37305ddb0541bdb4318c7d4ddc
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Morén, BjörnLarsson, TorbjörnCarlsson Tedgren, Åsa

Sök vidare i DiVA

Av författaren/redaktören
Morén, BjörnLarsson, TorbjörnCarlsson Tedgren, Åsa
Av organisationen
Tillämpad matematikTekniska fakultetenAvdelningen för diagnostik och specialistmedicinMedicinska fakultetenCentrum för medicinsk bildvetenskap och visualisering, CMIV
I samma tidskrift
Medical Physics
Annan matematikCancer och onkologi

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 421 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 529 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf