liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Novel pore size-controlled, susceptibility matched, 3D-printed MRI phantoms
Eunice Kennedy Shriver Natl Inst Child Hlth & Huma, MD 20892 USA.
Eunice Kennedy Shriver Natl Inst Child Hlth & Huma, MD 20892 USA; Ctr Neurosci & Regenerat Med, MD USA.
Eunice Kennedy Shriver Natl Inst Child Hlth & Huma, MD 20892 USA; NIA, MD USA.
Linköpings universitet, Institutionen för medicinsk teknik, Avdelningen för medicinsk teknik. Linköpings universitet, Tekniska fakulteten. Linköpings universitet, Centrum för medicinsk bildvetenskap och visualisering, CMIV. Spin Nord AB, Linköping, Sweden.ORCID-id: 0000-0003-0859-1311
Visa övriga samt affilieringar
2024 (Engelska)Ingår i: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 91, nr 6, s. 2431-2442Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

PurposeWe report the design concept and fabrication of MRI phantoms, containing blocks of aligned microcapillaires that can be stacked into larger arrays to construct diameter distribution phantoms or fractured, to create a "powder-averaged" emulsion of randomly oriented blocks for vetting or calibrating advanced MRI methods, that is, diffusion tensor imaging, AxCaliber MRI, MAP-MRI, and multiple pulsed field gradient or double diffusion-encoded microstructure imaging methods. The goal was to create a susceptibility-matched microscopically anisotropic but macroscopically isotropic phantom with a ground truth diameter that could be used to vet advanced diffusion methods for diameter determination in fibrous tissues.MethodsTwo-photon polymerization, a novel three-dimensional printing method is used to fabricate blocks of capillaries. Double diffusion encoding methods were employed and analyzed to estimate the expected MRI diameter.ResultsSusceptibility-matched microcapillary blocks or modules that can be assembled into large-scale MRI phantoms have been fabricated and measured using advanced diffusion methods, resulting in microscopic anisotropy and random orientation.ConclusionThis phantom can vet and calibrate various advanced MRI methods and multiple pulsed field gradient or diffusion-encoded microstructure imaging methods. We demonstrated that two double diffusion encoding methods underestimated the ground truth diameter.

Ort, förlag, år, upplaga, sidor
WILEY , 2024. Vol. 91, nr 6, s. 2431-2442
Nyckelord [en]
anisotropic phantom; DDE; diameter; DTI; random orientation
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:liu:diva-201311DOI: 10.1002/mrm.30029ISI: 001163861900001PubMedID: 38368618Scopus ID: 2-s2.0-85185671523OAI: oai:DiVA.org:liu-201311DiVA, id: diva2:1842440
Anmärkning

Funding Agencies|Intramural Research Program; National Institute of Child Health and Human Development; Center for Neuroscience and Regenerative Medicine; National Institute of General Medical Sciences; [K99GM140338-01]

Tillgänglig från: 2024-03-05 Skapad: 2024-03-05 Senast uppdaterad: 2025-03-13Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Özarslan, Evren

Sök vidare i DiVA

Av författaren/redaktören
Özarslan, Evren
Av organisationen
Avdelningen för medicinsk teknikTekniska fakultetenCentrum för medicinsk bildvetenskap och visualisering, CMIV
I samma tidskrift
Magnetic Resonance in Medicine
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 107 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf