liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Factors affecting the accuracy of blood alcohol determinations in clinical and forensic laboratories in Italy: Results of a 7-year proficiency testing study
AULSS 3, Italy.
AULSS 3, Italy.
AULSS 3, Italy.
Univ Padua, Italy.
Visa övriga samt affilieringar
2025 (Engelska)Ingår i: Forensic Science International, ISSN 0379-0738, E-ISSN 1872-6283, Vol. 370, artikel-id 112471Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The results of a 7-year proficiency study involving Italian laboratories measuring blood alcohol concentration (BAC) are reported. Two blood samples spiked with known amounts of ethanol were sent for analysis twice per year to approximately 50 laboratories across Italy. The blood samples were prepared according to ISO standards, which included optimized transport and storage conditions to ensure ethanol stability. Participants completed an online questionnaire detailing their analytical results along with other analytical details, including the use of GCFID or GC-MS, storage temperature, time between sample delivery and analysis, reference materials, replicate determinations, and volume of blood aliquot. The participants also confirmed whether or not they were accredited and what the measurement uncertainty was for determination of BAC. The results from analysis of 1171 blood samples (after elimination of outliers) were evaluated by calculating z-scores using robust statistical methods. The inter-laboratory standard deviation (SD) increased with blood alcohol concentration (r = 0.94, p < 0.001). Notably, a significant reduction in robust SD was observed between 2017 and 2023 (p = 0.01). The use of matrix-matched certified reference materials gave more accurate results with mean z-scores closer to zero. The choice of analytical method, storage conditions, time delays, and laboratory accreditation did not significantly influence z-scores. This study revealed that regular participation in inter-laboratory proficiency programs did contribute to improving analytical performance. The choice of certified reference material was the principal determinant of the accuracy of the results.

Ort, förlag, år, upplaga, sidor
ELSEVIER IRELAND LTD , 2025. Vol. 370, artikel-id 112471
Nyckelord [en]
Alcohol; Analysis; Blood-ethanol concentration; Forensic science; Legal medicine; Proficiency testing
Nationell ämneskategori
Övrig annan medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-213422DOI: 10.1016/j.forsciint.2025.112471ISI: 001471275800001PubMedID: 40222203Scopus ID: 2-s2.0-105002368510OAI: oai:DiVA.org:liu-213422DiVA, id: diva2:1956190
Tillgänglig från: 2025-05-05 Skapad: 2025-05-05 Senast uppdaterad: 2025-05-05

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Sök vidare i DiVA

Av författaren/redaktören
Jones, A Wayne
Av organisationen
Avdelningen för klinisk kemi och farmakologiMedicinska fakulteten
I samma tidskrift
Forensic Science International
Övrig annan medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 30 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf