liu.seSök publikationer i DiVA
Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Evaluation of startup time for a model contra-rotating pump-turbine in pump-mode
Department of Mechanics and Maritime Sciences, Chalmers University of Technology, SE-412 96 Gothenburg, Sweden.
Department of Mechanics and Maritime Sciences, Chalmers University of Technology, SE-412 96 Gothenburg, Sweden.
Department of Mechanics and Maritime Sciences, Chalmers University of Technology, SE-412 96 Gothenburg, Sweden.ORCID-id: 0000-0002-2037-8284
2022 (Engelska)Ingår i: IOP Conference Series: Earth and Environment, ISSN 1755-1307, E-ISSN 1755-1315, Vol. 1079, nr 1, artikel-id 012034Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A larger part of the electricity is today from intermittent renewable sources of energy. However, the energy production from such sources varies in time. Energy storage is one solution to compensate for this variation. Today pumped hydro storage (PHS) is the most common form of energy storage. Usually, it requires a large head, which limits where it can be built. In the EU project ALPHEUS, PHS technologies for low- to ultra-low heads are explored. One of the concepts is a contra-rotating pump-turbine (CRPT). The behaviour of this design at time-varying load conditions is today scarce. In the present work, the impact of the startup time for a CRPT is analysed through computational fluid dynamics (CFD) simulations. The analysis includes a comparison between a coarse and a fine CFD model. The coarse model produces acceptable results and is 50 times cheaper, this model is thus used to assess the startup time. It is found that longer startup times generate lesser loads and peak values. A startup time of 10 s may be a sufficient alternative as the peak loads are heavily reduced compared to faster startups. Furthermore, there is not much difference between a startup time of 20–30 s.

Ort, förlag, år, upplaga, sidor
IOP Publishing , 2022. Vol. 1079, nr 1, artikel-id 012034
Nationell ämneskategori
Strömningsmekanik
Identifikatorer
URN: urn:nbn:se:liu:diva-216697DOI: 10.1088/1755-1315/1079/1/012034Scopus ID: 2-s2.0-85141757453OAI: oai:DiVA.org:liu-216697DiVA, id: diva2:1990826
Tillgänglig från: 2025-08-21 Skapad: 2025-08-21 Senast uppdaterad: 2026-06-04

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Salehi, Saeed
I samma tidskrift
IOP Conference Series: Earth and Environment
Strömningsmekanik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 10 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf