liu.seSök publikationer i DiVA
Driftstörningar
Det förekommer återkommande driftstörningar på några av sök-portalerna på grund av hög belastning. Vi arbetar på att lösa problemet, ni kan tillfälligt mötas av ett felmeddelande.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Assessing contaminant leaching from concrete in water storage tanks using non-target screening
Linköpings universitet, Institutionen för fysik, kemi och biologi, Kemi. Linköpings universitet, Tekniska fakulteten. Department of Plant and Environmental Science, University of Copenhagen, Denmark.ORCID-id: 0009-0003-9820-5716
HOFOR A/S, Copenhagen, Denmark.
HOFOR A/S, Copenhagen, Denmark.
Department of Plant and Environmental Science, University of Copenhagen, Denmark.
Visa övriga samt affilieringar
2025 (Engelska)Ingår i: Environmental Science and Pollution Research, ISSN 0944-1344, E-ISSN 1614-7499Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Concrete is widely used for drinking water storage, yet it can leach organic compounds that may affect water quality. In response to the EU Drinking Water Directive (2021), all materials in contact with drinking water, including concrete, must be approved before installation by 2027. This study used non-target screening to support this process by analyzing chemical leaching from concrete. The three tested concrete types released similar compounds, mainly polyethylene glycols (PEGs), with the superplasticizer added during production, identified as the main source. A strong correlation (R2 = 0.998 for n = 3) between superplasticizer amount and leaching extent underscores the critical role of additives in chemical migration, emphasizing the need to assess their environmental implications for drinking water quality. No compounds from the retarder additive were found, while alkanolamines and fatty acids, likely from grinding and hydrophobic agents, were identified as leaches as well. The study highlights the importance of non-target screening to better understand the chemical impact of storage materials on drinking water safety.

Ort, förlag, år, upplaga, sidor
2025.
Nationell ämneskategori
Analytisk kemi
Identifikatorer
URN: urn:nbn:se:liu:diva-219593DOI: 10.1007/s11356-025-37239-wOAI: oai:DiVA.org:liu-219593DiVA, id: diva2:2015003
Tillgänglig från: 2025-11-19 Skapad: 2025-11-19 Senast uppdaterad: 2025-12-10

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Eriksson, VictoriaTisler, Selina
Av organisationen
KemiTekniska fakulteten
I samma tidskrift
Environmental Science and Pollution Research
Analytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 56 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf