Pursuing a hierarchical taxonomy in a water-cooled data center room
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem. Linköpings universitet, Tekniska fakulteten. Division of Building, Energy and Environment Technology, Department of Technology and Environment, University of Gävle, Gävle, Sweden.ORCID-id: 0000-0002-0604-3672
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem. Linköpings universitet, Tekniska fakulteten. Division of Building, Energy and Environment Technology, Department of Technology and Environment, University of Gävle, Gävle, Sweden.
Linköpings universitet, Institutionen för ekonomisk och industriell utveckling, Energisystem. Linköpings universitet, Tekniska fakulteten.ORCID-id: 0000-0002-6885-6118
Linköping Lab Operations, Ericsson AB, Linköping, Sweden.
Visa övriga samt affilieringar
2026 (Engelska)Ingår i: Scientific Reports, E-ISSN 2045-2322, Vol. 16, nr 1, artikel-id 26484Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Despite the growing number of scientific investigations on developing taxonomies in various industries and categorizing energy end-use (EEU) processes, research on such frameworks in the data center (DC) sector remains limited, restricting systematic analysis of energy use, benchmarking, and identification of energy efficiency measures. This study seeks to achieve two key objectives: (1) to create a hierarchical taxonomy for categorizing EEU process, (2) and to identify the most relevant energy performance indicators (EnPIs). The methodology combines hierarchical classification of energy flows with quantitative analysis based on time-resolved operational data, allowing for detailed analysis of dynamic system behaviour and allocation of energy use across processes, applied to a DC room with a detached in-rack water cooling system in Sweden operated by Ericsson. The results of this paper present a novel hierarchical taxonomy for a water-cooled DC room with six defined EEU processes, of which four are related to data processing processes and two to support processes. Notably, over 99.9% of total EEU is connected to data processing processes which is a significantly higher figure compared to other production processes in other sectors. Moreover, the established EnPIs can facilitate benchmarking between DCs with similar infrastructures and for monitoring the energy use of various EEU processes. The proposed methodology is transferable to other DC environments with comparable system boundaries and data availability, and its reproducibility is supported by the structured and data-driven methodology, which enables replication of the analytical approach given comparable data availability.

Ort, förlag, år, upplaga, sidor
Springer Nature, 2026. Vol. 16, nr 1, artikel-id 26484
Nyckelord [en]
Taxonomy; Data center; Detached in-rack water cooling system; Energy end-use; Energy performance indicators
Nationell ämneskategori
Energisystem
Identifikatorer
URN: urn:nbn:se:liu:diva-227255DOI: 10.1038/s41598-026-68222-1ISI: 001857486000006PubMedID: 42637796Scopus ID: 2-s2.0-105048127398OAI: oai:DiVA.org:liu-227255DiVA, id: diva2:2098103
Forskningsfinansiär
Linköpings universitetTillgänglig från: 2026-09-03 Skapad: 2026-09-03 Senast uppdaterad: 2026-09-21

Open Access i DiVA

fulltext(2690 kB)45 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 2690 kBChecksumma SHA-512
e48fa830083c5f84238a25e4e4b15c8b49f5efbe366a654c450e3ad78ef52ed5f87dd92508f7206844c1d8a35d609d3e48a9c0c84509f6ec5380f49db790a02b
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Milić, VlatkoThollander, PatrikAndersson, MariaMoshfegh, Bahram

Sök vidare i DiVA

Av författaren/redaktören
Milić, VlatkoThollander, PatrikAndersson, MariaMoshfegh, Bahram
Av organisationen
EnergisystemTekniska fakulteten
I samma tidskrift
Scientific Reports
Energisystem

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 45 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 546 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf