Difficulties for primary health care staff in interpreting bacterial findings on a device for simplified urinary culture
Clinical Microbiology Laboratory University Hospital Linköping.
Clinical Microbiology Akademiska laboratorierna, Uppsala.
EQUALIS AB Uppsala.
EQUALIS AB Uppsala.
Visa övriga samt affilieringar
2008 (Engelska)Ingår i: Scandinavian Journal of Clinical and Laboratory Investigation, ISSN 0036-5513, E-ISSN 1502-7686, Vol. 68, nr 4, s. 312-316Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The reliability of interpretations of findings from dip-slide devices for culturing urine was investigated in a national Swedish external quality assessment (EQA) programme. Also investigated was the extent of improvement in the examination procedure achieved through personnel training programmes and information. According to Swedish national recommendations, dip-slide should only be used in primary health care (PHC) in cases of uncomplicated urinary tract infection (UTI) in females of childbearing age. The recommendations also define six possible outcomes of a dip-slide examination, outcomes that have formed the basis for the EQA programme since 2001. No improvement in ability to classify readings correctly into the six categories was noted for the period 2001 to 2006. Preparations containing 'mixed flora' presented participants with the greatest difficulty, with only 28% correct reports. The EQA programme, with educational components and voluntary participation, has not improved quality. The disappointing results might be a reflection of the limited effort and resources allocated by clinical microbiology laboratories for training and for sustaining proficiency in the evaluation of dip-slides. For these reasons, we cannot at present recommend the dip-slide technique for use in PHC settings. © 2008 Informa UK Ltd (Informa Healthcare, Taylor & Francis AS).

Ort, förlag, år, upplaga, sidor
2008. Vol. 68, nr 4, s. 312-316
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-43406DOI: 10.1080/00365510701759703Lokalt ID: 73760OAI: oai:DiVA.org:liu-43406DiVA, id: diva2:264265
Tillgänglig från: 2009-10-10 Skapad: 2009-10-10 Senast uppdaterad: 2017-12-13

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltexthttp://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&dopt=Citation&list_uids=18609088

Person

Forsum, Urban

Sök vidare i DiVA

Av författaren/redaktören
Forsum, Urban
Av organisationen
HälsouniversitetetKlinisk mikrobiologiKlinisk mikrobiologi
I samma tidskrift
Scandinavian Journal of Clinical and Laboratory Investigation
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 129 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf