liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Silane-dextran chemistry on lateral flow polymer chips for immunoassays
Jönsson, C., Åmic AB, Uppsala, Sweden, Biomedical Diagnostics Institute, NCSR Building, Dublin City University, Glasnevin Dublin 9, Ireland.
Åmic AB, Uppsala, Sweden.
Rundström, G., Åmic AB, Uppsala, Sweden.
Åmic AB, Uppsala, Sweden.
Visa övriga samt affilieringar
2008 (Engelska)Ingår i: Lab on a Chip, ISSN 1473-0197, E-ISSN 1473-0189, Vol. 8, nr 7, s. 1191-1197Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The prognosis for patients suffering from cardiovascular and many other diseases can be substantially improved if diagnosed at an early stage. High performance diagnostic testing using disposable microfluidic chips can provide a platform for realizing this vision. Åmic AB (Uppsala, Sweden) has developed a new microfluidic test chip for sandwich immunoassays fabricated by injection molding of the cycloolefin-copolymer Zeonor™. A highly ordered array of micropillars within the fluidic chip distributes the sample solution by capillary action. Since wetting of the pillar array surface is the only driving force for liquid distribution precise control of the surface chemistry is crucial. In this work we demonstrate a novel protocol for surface hydrophilization and antibody immobilization on cycloolefin-copolymer test chips, based on direct silanisation of the thermoplastic substrate. Dextran is subsequently covalently coupled to amino groups, thus providing a coating with a low contact angle suitable for antibody immobilization. The contact angle of dextran coated chips is stable for at least two months, which enables production of large batches that can be stored for extended periods of time. We demonstrate the utility of the presented platform and surface chemistry in a C-reactive protein assay with a detection limit of 2.6 ng ml-1, a dynamic range of 102 and a coefficient of variance of 15%. © The Royal Society of Chemistry.

Ort, förlag, år, upplaga, sidor
2008. Vol. 8, nr 7, s. 1191-1197
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
URN: urn:nbn:se:liu:diva-45778DOI: 10.1039/b800297eOAI: oai:DiVA.org:liu-45778DiVA, id: diva2:266674
Tillgänglig från: 2009-10-11 Skapad: 2009-10-11 Senast uppdaterad: 2017-12-13

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Martinsson, ErikLiedberg, Bo

Sök vidare i DiVA

Av författaren/redaktören
Martinsson, ErikLiedberg, Bo
Av organisationen
Sensorvetenskap och MolekylfysikTekniska högskolan
I samma tidskrift
Lab on a Chip
Teknik och teknologier

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 308 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf