liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Roentgen Stereophotogrammetric Analysis of Motion between the Bone and the Socket in a Transtibial Amputation Prosthesis: A Case Study
Söderberg, B., Scandinavian Orthopaedic Laboratory, Helsingborg Hospital, Helsingborg, Sweden, Scandinavian Orthopaedic Laboratory, Helsingborg Hospital, 251 87 Helsingborg, Sweden.
Linköpings universitet, Hälsouniversitetet. Linköpings universitet, Institutionen för klinisk och experimentell medicin, Ortopedi och idrottsmedicin.
Department of Orthopaedics, University Hospital, Lund, Sweden.
2003 (Engelska)Ingår i: Journal of prosthetics and orthotics, ISSN 1040-8800, E-ISSN 1534-6331, Vol. 15, nr 3, s. 95-99Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

High-tech development within prosthetics for lower limb amputees can benefit from high-tech methods to study the socket fit. Roentgen stereophotogrammetry is one such method with high resolution to study stability with point motion and segment motion simultaneously to show how well bonded the socket is to the stump. It has been used to follow results of total joint replacement concerning loosening and wear of components. In this study, one transtibial amputee was examined with tantalum bone markers implanted through skin and also glued into the hard socket. Four different prosthetic suspensions were used, and we simulated four different gait cycle positions and recorded the micromotions between the tibial bone segment and the hard socket three-dimensionally. The vertical motion varied 10 to 30 mm and the AP motion 0 to 15 mm. For the first time, we could measure rotation of the socket on the stump about a vertical axis. The rotation in the transversal plane was 7.5 outward. Airtight sleeve with expulsion valve gave the best stability.

Ort, förlag, år, upplaga, sidor
2003. Vol. 15, nr 3, s. 95-99
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-46580DOI: 10.1097/00008526-200307000-00008OAI: oai:DiVA.org:liu-46580DiVA, id: diva2:267476
Tillgänglig från: 2009-10-11 Skapad: 2009-10-11 Senast uppdaterad: 2017-12-13

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Ryd, Leif

Sök vidare i DiVA

Av författaren/redaktören
Ryd, Leif
Av organisationen
HälsouniversitetetOrtopedi och idrottsmedicin
I samma tidskrift
Journal of prosthetics and orthotics
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 166 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf