Ion implantation of silicon carbide
Hallén, A., Department of Electronics, Royal Institute of Technology, P.O. Box Electrum 229, S 164 40 Kista, Sweden.
Department of Electronics, Royal Institute of Technology, P.O. Box Electrum 229, S 164 40 Kista, Sweden.
Department of Electronics, Royal Institute of Technology, P.O. Box Electrum 229, S 164 40 Kista, Sweden.
Åberg, D., Department of Electronics, Royal Institute of Technology, P.O. Box Electrum 229, S 164 40 Kista, Sweden.
Visa övriga samt affilieringar
2002 (Engelska)Ingår i: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, ISSN 0168-583X, E-ISSN 1872-9584, Vol. 186, nr 1-4, s. 186-194Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Ion implantation is an important technique for a successful implementation of commercial SiC devices. Much effort has also been devoted to optimising implantation and annealing parameters to improve the electrical device characteristics. However, there is a severe lack of understanding of the fundamental implantation process and the generation and annealing kinetics of point defects and defect complexes. Only very few of the most elementary intrinsic point defects have been unambiguously identified so far. To reach a deeper understanding of the basic mechanisms SiC samples have been implanted with a broad range of ions, energies, doses, etc., and the resulting defects and damage produced in the lattice have been studied with a multitude of characterisation techniques. In this contribution we will review some of the results generated recently and also try to indicate where more research is needed. In particular, deep level transient spectroscopy (DLTS) has been used to investigate point defects at very low doses and transmission electron microscopy (TEM) and Rutherford backscattering spectrometry (RBS) are used for studying the damage build-up at high doses. © 2002 Elsevier Science B.V. All rights reserved.

Ort, förlag, år, upplaga, sidor
2002. Vol. 186, nr 1-4, s. 186-194
Nyckelord [en]
Annealing, Damage, Dislocation loops, Dose rate, Point defects
Nationell ämneskategori
Teknik och teknologier
Identifikatorer
URN: urn:nbn:se:liu:diva-47150DOI: 10.1016/S0168-583X(01)00880-1OAI: oai:DiVA.org:liu-47150DiVA, id: diva2:268046
Tillgänglig från: 2009-10-11 Skapad: 2009-10-11 Senast uppdaterad: 2017-12-13

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Persson, PerCarlsson, FredrikStorasta, LiutaurasBergman, Peder

Sök vidare i DiVA

Av författaren/redaktören
Persson, PerCarlsson, FredrikStorasta, LiutaurasBergman, Peder
Av organisationen
Tekniska högskolanTunnfilmsfysikInstitutionen för fysik, kemi och biologiMateriefysik
I samma tidskrift
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Teknik och teknologier

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 250 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf