Comparing ambient, air-convection, and fluid-convection heating techniques in treating hypothermic burn patients, a clinical RCT
Östergötlands Läns Landsting, Sinnescentrum, Hand- och plastikkirurgiska kliniken US.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Yrkes- och miljömedicin. Linköpings universitet, Hälsouniversitetet.
Linköpings universitet, Institutionen för klinisk och experimentell medicin. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Barn- och kvinnocentrum, Barn- och ungdomskliniken i Linköping.
Linköpings universitet, Institutionen för klinisk och experimentell medicin, Brännskadevård. Linköpings universitet, Hälsouniversitetet. Östergötlands Läns Landsting, Sinnescentrum, Hand- och plastikkirurgiska kliniken US. Östergötlands Läns Landsting, Sinnescentrum, Anestesi- och operationkliniken US.
Visa övriga samt affilieringar
2011 (Engelska)Ingår i: Annals of Surgical Innovation and Research, E-ISSN 1750-1164, Vol. 5Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: Hypothermia in burns is common and increases morbidity and mortality. Several methods are available to reach and maintain normal core body temperature, but have not yet been evaluated in critical care for burned patients. Our units ordinary technique for controlling body temperature (Bair Hugger®+ radiator ceiling + bed warmer + Hotline®) has many drawbacks e.g.; slow and the working environment is hampered.The aim of this study was to compare our ordinary heating technique with newly-developed methods: the Allon™2001 Thermowrap (a temperature regulating water-mattress), and Warmcloud (a temperature regulating air-mattress).Methods: Ten consecutive burned patients (andgt; 20% total burned surface area and a core temperature andlt; 36.0C) were included in this prospective, randomised, comparative study. Patients were randomly exposed to 3 heating methods. Each treatment/measuring-cycle lasted for 6 hours. Each heating method was assessed for 2 hours according to a randomised timetable. Core temperature was measured using an indwelling (bladder) thermistor. Paired t-tests were used to assess the significance of differences between the treatments within the patients. ANOVA was used to assess the differences in temperature from the first to the last measurement among all treatments. Three-way ANOVA with the Tukey HSD post hoc test and a repeated measures ANOVA was used in the same manner, but included information about patients and treatment/measuring-cycles to control for potential confounding. Data are presented as mean (SD) and (range). Probabilities of less than 0.05 were accepted as significant.Results: The mean increase, 1.4 (SD 0.6C; range 0.6-2.6C) in core temperature/treatment/measuring-cycle highly significantly favoured the Allon™2001 Thermowrap in contrast to the conventional method 0.2 (0.6)C (range -1.2 to 1.5C) and the Warmcloud 0.3 (0.4)C (range -0.4 to 0.9C). The procedures for using the Allon™2001 Thermowrap were experienced to be more comfortable and straightforward than the conventional method or the Warmcloud.Conclusions: The Allon™2001 Thermowrap was more effective than the Warmcloud or the conventional method in controlling patients temperatures. © 2011 Kjellman et al; licensee BioMed Central Ltd.

Ort, förlag, år, upplaga, sidor
BioMed Central , 2011. Vol. 5
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:liu:diva-75560DOI: 10.1186/1750-1164-5-4OAI: oai:DiVA.org:liu-75560DiVA, id: diva2:508217
Tillgänglig från: 2012-03-07 Skapad: 2012-03-07 Senast uppdaterad: 2024-03-14

Open Access i DiVA

fulltext(744 kB)735 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 744 kBChecksumma SHA-512
021e27b5fa3bcc7a50ce06c95d475a4536246bab6f60359cfeaa2208fa7eb5dd337013ecea38f34dc1ce7cb4ec412f5430ebfc465be2292628a42feddfe61517
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Person

Fredrikson, MatsGlad Mattsson, GunillaSjöberg, FolkeHuss, Fredrik

Sök vidare i DiVA

Av författaren/redaktören
Fredrikson, MatsGlad Mattsson, GunillaSjöberg, FolkeHuss, Fredrik
Av organisationen
Hand- och plastikkirurgiska kliniken USYrkes- och miljömedicinHälsouniversitetetInstitutionen för klinisk och experimentell medicinBarn- och ungdomskliniken i LinköpingBrännskadevårdAnestesi- och operationkliniken US
I samma tidskrift
Annals of Surgical Innovation and Research
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 738 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 799 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf