Standardized Evaluation System for Left Ventricular Segmentation Algorithms in 3D Echocardiography
University of Lyon 1, France.
Erasmus MC, Netherlands.
Katholieke University of Leuven, Belgium.
Katholieke University of Leuven, Belgium.
Visa övriga samt affilieringar
2016 (Engelska)Ingår i: IEEE Transactions on Medical Imaging, ISSN 0278-0062, E-ISSN 1558-254X, Vol. 35, nr 4, s. 967-977Artikel i tidskrift (Refereegranskat) Published
Resurstyp
Text
Abstract [en]

Real-time 3D Echocardiography (RT3DE) has been proven to be an accurate tool for left ventricular (LV) volume assessment. However, identification of the LV endocardium remains a challenging task, mainly because of the low tissue/blood contrast of the images combined with typical artifacts. Several semi and fully automatic algorithms have been proposed for segmenting the endocardium in RT3DE data in order to extract relevant clinical indices, but a systematic and fair comparison between such methods has so far been impossible due to the lack of a publicly available common database. Here, we introduce a standardized evaluation framework to reliably evaluate and compare the performance of the algorithms developed to segment the LV border in RT3DE. A database consisting of 45 multivendor cardiac ultrasound recordings acquired at different centers with corresponding reference measurements from three experts are made available. The algorithms from nine research groups were quantitatively evaluated and compared using the proposed online platform. The results showed that the best methods produce promising results with respect to the experts measurements for the extraction of clinical indices, and that they offer good segmentation precision in terms of mean distance error in the context of the experts variability range. The platform remains open for new submissions.

Ort, förlag, år, upplaga, sidor
IEEE Press, 2016. Vol. 35, nr 4, s. 967-977
Nyckelord [en]
Endocardium; left ventricle segmentation; real-time 3D echocardiography; standardized evaluation system
Nationell ämneskategori
Klinisk medicin
Identifikatorer
URN: urn:nbn:se:liu:diva-127780DOI: 10.1109/TMI.2015.2503890ISI: 000374164800004PubMedID: 26625409OAI: oai:DiVA.org:liu-127780DiVA, id: diva2:927617
Anmärkning

Funding agencies: Riksbankens Jubileumsfond; VINNOVA

Tillgänglig från: 2016-05-12 Skapad: 2016-05-12 Senast uppdaterad: 2021-08-05

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Person

Smedby, Örjan

Sök vidare i DiVA

Av författaren/redaktören
Wang, ChenSmedby, Örjan
Av organisationen
Institutionen för medicin och hälsaMedicinska fakultetenCentrum för medicinsk bildvetenskap och visualisering, CMIVAvdelningen för radiologiska vetenskaperRöntgenkliniken i Linköping
I samma tidskrift
IEEE Transactions on Medical Imaging
Klinisk medicin

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 479 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf