liu.seSök publikationer i DiVA
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Efficacy and safety of the Lotus Valve System for treatment of patients with severe aortic valve stenosis and intermediate surgical risk: Results from the Nordic Lotus-TAVR registry
Copenhagen University Hospital, Denmark.
Skåne University Hospital, Sweden.
Helsinki University Hospital, Finland.
Haukeland Hospital, Norway.
Visa övriga samt affilieringar
2016 (Engelska)Ingår i: International Journal of Cardiology, ISSN 0167-5273, E-ISSN 1874-1754, Vol. 219, s. 92-97Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background: Transcatheter aortic valve replacement (TAVR) has becomean established therapeutic option for patients with symptomatic, severe aortic valve stenosis (AS) who are ineligible or at high risk for conventional valvular surgery. In Northwestern Europe, the TAVR technology is also increasingly used to treat patients with an intermediate risk profile. Methods and results: The study was designed as an independent Nordic multicenter registry of intermediate risk patients treated with the Lotus Valve System (Boston Scientific, MA, USA; N = 154). Valve Academic Research Consortium (VARC)-defined device success was obtained in 97.4%. A Lotus Valve was successfully implanted in all patients. There was no valve migration, embolization, ectopic valve deployment, or TAV-in-TAV deployment. The VARC-defined combined safety rate at 30 days was 92.2%, with a mortality rate of 1.9% and stroke rate of 3.2%. The clinical efficacy rate after 30 days was 91.6% - only one patient had moderate aortic regurgitation. When considering only those patients in the late experience group (N=79), the combined safety and clinical efficacy rates were 93.7% and 92.4%, respectively. The pacemaker implantation rate was 27.9% - this rate was 12.8% in case of a combined implantation depth amp;lt;4 mm and a device/annulus ratio amp;lt; 1.05. Conclusions: The present study demonstrates the efficacy and safety of the repositionable, retrievable Lotus Valve System in intermediate risk patients with AS. The VARC-defined device success rate was 97.4% with a 30-day patient safety and clinical efficacy rate of more than 90%. Less than moderate aortic regurgitation was obtained in 99.4% of patients. (C) 2016 Elsevier Ireland Ltd. All rights reserved.

Ort, förlag, år, upplaga, sidor
Elsevier, 2016. Vol. 219, s. 92-97
Nyckelord [en]
Aortic valve stenosis, Transcatheter aortic valve replacement, Intermediate risk, Safety, Efficacy
Nationell ämneskategori
Kardiologi och kardiovaskulära sjukdomar
Identifikatorer
URN: urn:nbn:se:liu:diva-131161DOI: 10.1016/j.ijcard.2016.05.072ISI: 000380817400015PubMedID: 27288972OAI: oai:DiVA.org:liu-131161DiVA, id: diva2:972254
Tillgänglig från: 2016-09-20 Skapad: 2016-09-12 Senast uppdaterad: 2025-02-10Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Sök vidare i DiVA

Av författaren/redaktören
Nielsen, Niels Erik
Av organisationen
Avdelningen för kardiovaskulär medicinHälsouniversitetetKardiologiska kliniken USMedicinska fakultetenFysiologiska kliniken US
I samma tidskrift
International Journal of Cardiology
Kardiologi och kardiovaskulära sjukdomar

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 864 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf