Impact of the I-value of diamond on the energy deposition in different beam qualities
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences.ORCID iD: 0000-0002-8565-0680
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Department of Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.ORCID iD: 0000-0002-4549-8303
Facultat de Física (FQA and ICC), Universitat de Barcelona, Barcelona, Catalonia, Spain.
2021 (English)In: Physics in Medicine and Biology, ISSN 0031-9155, E-ISSN 1361-6560, Vol. 66, no 12, article id 125004Article in journal (Refereed) Published
Abstract [en]

Diamond detectors are increasingly employed in dosimetry. Their response has been investigated by means of Monte Carlo (MC) methods, but there is no consensus on what mass density ρ, mean excitation energy I and number of conduction electrons per atom nce to use in the simulations. The ambiguity occurs due to its seeming similarity with graphite (both are carbon allotropes). Contrary to diamond, graphite has been well-characterized. Except for the difference in ρ between crystalline graphite (2.265 g cm-3) and diamond (3.515 g cm-3), their dielectric properties are assumed to be identical. This is incorrect, and the two materials should be distinguished: (ρ = 2.265 g cm-3, I = 81.0 eV, nce = 1) for graphite and (ρ = 3.515 g cm-3, I = 88.5 eV, nce = 0) for diamond. Simulations done with the MC code PENELOPE show that the energy imparted in diamond decreases by up to 1% with respect to 'pseudo-diamond' (ρ = 3.515 g cm-3, I = 81.0 eV, nce = 0) depending on the beam quality and cavity thickness. The energy imparted changed the most in cavities that are small compared with the range of electrons. The difference in the density-effect term relative to graphite was the smallest for diamond owing to an interplay effect that ρ, I and nce have on this term, in contrast to pseudo-diamond media when either ρ or I alone were adjusted. The study also presents a parameterized density-effect correction function for diamond that may be used by MC codes like EGSnrc. The ESTAR program assumes that nce = 2 for all carbon-based materials, hence it delivers an erroneous density-effect correction term for graphite and diamond. Despite the small changes of the energy imparted in diamond simulated with two different I values and expected close-to-negligible deviation from the published small-field output correction data, it is important to pay attention to material properties and model the medium faithfully.

Place, publisher, year, edition, pages
Institute of Physics (IOP), 2021. Vol. 66, no 12, article id 125004
Keywords [en]
Diamond, graphite, mass electronic stopping power, density-effect correction, Monte Carlo simulation
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-176110DOI: 10.1088/1361-6560/ac028fISI: 000658482300001PubMedID: 34014176OAI: oai:DiVA.org:liu-176110DiVA, id: diva2:1561247
Note

Funding: Swedish Cancer Society (Cancerfonden)Swedish Cancer Society [CAN 2017/1029, CAN 2018/622]; Spanish Ministerio de Ciencia, Innovacion y Universidades [PGC2018-096788-B-I00]

Available from: 2021-06-07 Created: 2021-06-07 Last updated: 2021-12-17Bibliographically approved
In thesis
1. Development of Experimental Brachytherapy Dosimetry Using Monte Carlo Simulations for Detector Characterization
Open this publication in new window or tab >>Development of Experimental Brachytherapy Dosimetry Using Monte Carlo Simulations for Detector Characterization
2021 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Brachytherapy (BT) is a type of interventional radiotherapy that is advantageous due to high absorbed dose conformity and possibility to deliver high dose in few fractions. It is often used for prostate and gynecological tumors as monotherapy or a boost alongside external beam radiotherapy (EBRT). However, there is a number of things that can compromise treatment delivery, starting from incorrect source data in a treatment planning system to malfunctioning of a treatment delivery unit. None of the established quality assurance (QA) procedures emulate treatment delivery where the planned dose could be compared with the experimentally determined value. While such practices are employed in EBRT, BT suffers from the lack of detectors that would be water-equivalent and convenient to use for regular measurements. First-choice thermoluminescence dosimeters are water-equivalent but have passive readout. Sporadic attempts to use other detectors have not led to any established practices at clinical sites. Stepping ahead, the safety of treatment delivery could be further evaluated using real-time in vivo dosimetry. If detectors were characterized with high-accuracy, a reliable error detection level could be set to terminate treatments if needed. Contrary to in-phantom QA, there are detectors suitable for such applications but their characterization is incomplete. In this thesis we address both problems.

Focusing on high-dose-rate 192Ir remote afterloading treatments, which are among the most common in BT, we investigate and propose a direct readout synthetic diamond detector for in-phantom QA of treatment units. The detector was designed for small-field high-energy EBRT dosimetry but our findings demonstrate its suitability for BT dosimetry. Additionally, due to detector calibration with traceability to absorbed dose to water primary standards of high-energy photon beams and combined experimental and Monte Carlo (MC) characterization, the uncertainties in absorbed dose to water were comparable to passive readout detectors and lower than for other direct readout detectors. We complemented detector investigation with a theoretical study on diamond material properties and which values (mass density, mean excitation energy, number of conduction electrons per atom) shall be used for the most faithful description of ionizing radiation interactions in diamond for MC simulations and calculations of mass electronic stopping power. The findings improve diamond dosimetry accuracy, and subsequently, experimental dosimetry of not only BT but all radiotherapy beam qualities where the detectors are used.

Aiming to further contribute to experimental BT dosimetry, we focused on high atomic number inorganic scintillators used for in vivo dosimetry: ZnSe, CsI, and Al2O3. These are already existing dosimeters exhibiting promising luminescence properties, but until now, their investigation has been solely experimental. MC simulations are not subject to detector positioning uncertainties which are high due to steep dose gradients and other detector response artifacts, thus we used the method to investigate the absorbed-dose energy response of detectors, its dependence on radial distance and polar angles, scatter conditions, as well as detector design. We clarified how error-prone high atomic number detector characterization might be if experimental and MC methods are not combined. Both have certain limitations and have to complement each other.

Though the thesis addresses two different types of detectors for two different applications, the underlying theme is to understand the detector at hand. The use of MC simulations allowed introducing a new synthetic diamond detector into BT field and improving accuracy of in vivo dosimetry systems using inorganic scintillators. We also raised awareness to the lack of unified detector calibration and characterization practice in BT dosimetry.

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2021. p. 49
Series
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1775
Keywords
Dosimetry, brachytherapy, solid-state detectors, Monte Carlo
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
urn:nbn:se:liu:diva-175192 (URN)10.3384/diss.diva-175192 (DOI)9789179296766 (ISBN)
Public defence
2021-06-10, Belladonna, Building 511, Campus US, Linköping, 14:00 (English)
Opponent
Supervisors
Available from: 2021-04-26 Created: 2021-04-26 Last updated: 2021-10-13Bibliographically approved

Open Access in DiVA

fulltext(486 kB)341 downloads
File information
File name FULLTEXT01.pdfFile size 486 kBChecksum SHA-512
438e9588127df26051a3f056dee88f270b0e53ce3e31b473d29afdc2b82bc618107d97adc89601c9bf7bd1d573cac9db78a30cc76f0eb5f9cb290c3e87494139
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Authority records

Kaveckyte, VaivaCarlsson Tedgren, Åsa

Search in DiVA

By author/editor
Kaveckyte, VaivaCarlsson Tedgren, Åsa
By organisation
Division of Diagnostics and Specialist MedicineFaculty of Medicine and Health Sciences
In the same journal
Physics in Medicine and Biology
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 341 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 254 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf