liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Image quality in CT thorax: effect of altering reconstruction algorithm and tube load: Image quality in CT thorax
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Region Östergötland, Center for Diagnostics, Department of Radiology in Linköping. Linköping University, Center for Medical Image Science and Visualization (CMIV). Linköping University, Faculty of Medicine and Health Sciences.ORCID iD: 0000-0002-4013-4615
Linköping University, Center for Medical Image Science and Visualization (CMIV). Region Östergötland, Center for Diagnostics, Department of Radiology in Linköping. Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences.ORCID iD: 0000-0003-0066-4985
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Region Östergötland, Center for Diagnostics, Medical radiation physics. Linköping University, Faculty of Medicine and Health Sciences.
Linköping University, Center for Medical Image Science and Visualization (CMIV). Region Östergötland, Center for Diagnostics, Medical radiation physics. Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences.ORCID iD: 0000-0003-3352-8330
Show others and affiliations
2024 (English)In: Radiation Protection Dosimetry, ISSN 0144-8420, E-ISSN 1742-3406, Vol. 200, no 5, p. 504-514Article in journal (Refereed) Published
Abstract [en]

Non-linear properties of iterative reconstruction (IR) algorithms can alter image texture. We evaluated the effect of a model-basedIR algorithm (advanced modelled iterative reconstruction; ADMIRE) and dose on computed tomography thorax image quality.Dual-source scanner data were acquired at 20, 45 and 65 reference mAs in 20 patients. Images reconstructed with filteredback projection (FBP) and ADMIRE Strengths 3–5 were assessed independently by six radiologists and analysed using an ordinallogistic regression model. For all image criteria studied, the effects of tube load 20 mAs and all ADMIRE strengths were significant(p < 0.001) when compared to reference categories 65 mAs and FBP. Increase in tube load from 45 to 65 mAs showed imagequality improvement in three of six criteria. Replacing FBP with ADMIRE significantly improves perceived image quality for allcriteria studied, potentially permitting a dose reduction of almost 70% without loss in image quality

Place, publisher, year, edition, pages
Oxford University Press, 2024. Vol. 200, no 5, p. 504-514
Keywords [en]
Visual grading regression (VGR), image quality, slice thickness, iterative reconstruction, and dose reduction
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-201119DOI: 10.1093/rpd/ncae005ISI: 001163879200001PubMedID: 38369635OAI: oai:DiVA.org:liu-201119DiVA, id: diva2:1840032
Funder
Swedish Heart Lung Foundation, 2022-0490Region Östergötland, RÖ-724631Region Östergötland, RÖ620341Region Östergötland, ALF RÖ-602731Region Östergötland, ALF RÖ697941
Note

Funding: Region Ostergotland; Medical Faculty at Linkoping University; Avtal Lakarutbildning och Forskning (ALF) [RO-602731, RO-697941]; Forskning och Utveckling (FoU) [RO-724631, RO-620341]; Region financiered Forskning och Utbildning (RFoU); Swedish Heart-Lung Foundation [2022-0490]

Available from: 2024-02-22 Created: 2024-02-22 Last updated: 2024-04-11Bibliographically approved

Open Access in DiVA

fulltext(1134 kB)124 downloads
File information
File name FULLTEXT01.pdfFile size 1134 kBChecksum SHA-512
f7ac1cd18e97b0074d9cf800d47c7beb2dc18257b3b2d15e95832388c369111441a354f7ce1655d133ffdc5c68ab6373634c0a57fcf1f2298df0f6ec274883e6
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Authority records

Kataria, BhartiWoisetschläger, MischaNilsson Althén, JonasSandborg, MichaelSmedby, Örjan

Search in DiVA

By author/editor
Kataria, BhartiWoisetschläger, MischaNilsson Althén, JonasSandborg, MichaelSmedby, Örjan
By organisation
Division of Diagnostics and Specialist MedicineDepartment of Radiology in LinköpingCenter for Medical Image Science and Visualization (CMIV)Faculty of Medicine and Health SciencesMedical radiation physics
In the same journal
Radiation Protection Dosimetry
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 126 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 233 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf