Optimization of photon counting CT for cardiac imaging in patients with left ventricular assist devices: An in-depth assessment of metal artifacts
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Linköping University, Center for Medical Image Science and Visualization (CMIV). Vestfold Hosp, Norway.
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Heart Center, Department of Thoracic and Vascular Surgery. Linköping University, Center for Medical Image Science and Visualization (CMIV).
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Diagnostics, Department of Radiology in Linköping. Linköping University, Center for Medical Image Science and Visualization (CMIV).ORCID iD: 0000-0001-5485-6769
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Diagnostics, Department of Radiology in Linköping. Linköping University, Center for Medical Image Science and Visualization (CMIV).
Show others and affiliations
2024 (English)In: Journal of Applied Clinical Medical Physics, E-ISSN 1526-9914, Vol. 25, no 7, article id e14386Article in journal (Refereed) Published
Abstract [en]

PurposePhoton counting CT (PCCT) holds promise for mitigating metal artifacts and can produce virtual mono-energetic images (VMI), while maintaining temporal resolution, making it a valuable tool for characterizing the heart. This study aimed to evaluate and optimize PCCT for cardiac imaging in patients during left ventricular assistance device (LVAD) therapy by conducting an in-depth objective assessment of metal artifacts and visual grading.MethodsVarious scan and reconstruction settings were tested on a phantom and further evaluated on a patient acquisition to identify the optimal protocol settings. The phantom comprised an empty thoracic cavity, supplemented with heart and lungs from a cadaveric lamb. The heart was implanted with an LVAD (HeartMate 3) and iodine contrast. Scans were performed on a PCCT (NAEOTOM Alpha, Siemens Healthcare). Metal artifacts were assessed by three objective methods: Hounsfield units (HU)/SD measurements (DiffHU and SDARTIFACT), Fourier analysis (AmplitudeLowFreq), and depicted LVAD volume in the images (BloomVol). Radiologists graded metal artifacts and the diagnostic interpretability in the LVAD lumen, cardiac tissue, lung tissue, and spinal cord using a 5-point rating scale. Regression and correlation analysis were conducted to determine the assessment method most closely associated with acquisition and reconstruction parameters, as well as the objective method demonstrating the highest correlation with visual grading.ResultsDue to blooming artifacts, the LVAD volume fluctuated between 27.0 and 92.7 cm3. This variance was primarily influenced by kVp, kernel, keV, and iMAR (R2 = 0.989). Radiologists favored pacemaker iMAR, 3 mm slice thickness, and T3D keV and kernel Bv56f for minimal metal artifacts in cardiac tissue assessment, and 110 keV and Qr40f for lung tissue interpretation. The model adequacy for DiffHU SDARTIFACT, AmplitueLowFreq, and BloomVol was 0.28, 0.76, 0.29, and 0.99 respectively for phantom data, and 0.95, 0.98, 1.00, and 0.99 for in-vivo data. For in-vivo data, the correlation between visual grading (VGSUM) and DiffHU SDARTIFACT, AmplitueLowFreq, and BloomVol was -0.16, -0.01, -0.48, and -0.40 respectively.ConclusionWe found that optimal scan settings for LVAD imaging involved using 120 kVp and IQ level 80. Employing T3D with pacemaker iMAR, the sharpest allowed vascular kernel (Bv56f), and VMI at 110 keV with kernel Qr40 yields images suitable for cardiac imaging during LVAD-therapy. Volumetric measurements of the LVAD for determination of the extent of blooming artifacts was shown to be the best objective method to assess metal artifacts.

Place, publisher, year, edition, pages
WILEY , 2024. Vol. 25, no 7, article id e14386
Keywords [en]
heart; left ventricular assistance device; metal artifact; myocardium; photon-counting computed tomography
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-203749DOI: 10.1002/acm2.14386ISI: 001219658800001PubMedID: 38739330Scopus ID: 2-s2.0-85192926572OAI: oai:DiVA.org:liu-203749DiVA, id: diva2:1861472
Note

Funding Agencies|CMIV; Swedish Research Council [2022-03931]; Swedish Heart and Lung Foundation [20210441]; ALF Grants Region Ostergotland [ROE-987498]; Sweden's Innovation Agency VINNOVA [2019-02261]; Foundation Linkoepings Laekaresaellskap Research Fund

Available from: 2024-05-28 Created: 2024-05-28 Last updated: 2026-03-13
In thesis
1. The Assisted Heart: Function and flow during left ventricular assistance
Open this publication in new window or tab >>The Assisted Heart: Function and flow during left ventricular assistance
2025 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Durable left ventricular assist device (LVAD) therapy has been revolutionised by the HeartMate 3™ (HM3), a fully magnetically levitated centrifugal pump, offering superior haemocompatibility and durability. However, long-term outcomes remain limited by complications such as aortic regurgitation (AR), right ventricular failure (RHF), and extrinsic outflow graft obstruction (eOGO). The current clinical standard for haemodynamic monitoring, echocardiography, is restricted by poor acoustic windows caused by the metallic body of the device. The overarching aim of this thesis was to investigate how HM3 therapy interacts with the native heart´s function and haemodynamics, employing photon-counting computed tomography (PCCT) as the foundation for new advanced imaging approaches.

The thesis comprises five papers. Paper I systematically reviewed echocardiographic evidence in HM3 recipients specifically, identifying AR, RHF, and interventricular interplay as key unresolved challenges. Paper II optimised PCCT acquisition and reconstruction protocols, demonstrating that tailored strategies can markedly reduce metal artefacts. Paper III combined PCCT-derived geometries with computational fluid dynamics (CFD) in cases of suspected eOGO, showing that anatomical narrowing does not invariably result in haemodynamic compromise. Paper IV applied a more advanced CFD-modelling approach at different degrees of AR, revealing that even mild regurgitation can induce a blind-loop circulation, a haemodynamic phenomenon with substantial loss of effective systemic output when the loop-circulation increases. Paper V analysed right ventricular volumetric variables across varying pump speeds, demonstrating progressive dilatation and reduced ejection fraction at higher speeds, with impaired contractile reserve – changes that could not be detected by concomitant echocardiographic variables.

In conclusion, by integrating artefact-reduced PCCT with image processing and flow modelling, this thesis provides mechanistic insights into device-heart interactions that cannot be captured by conventional methods. The findings indicate that radiologically identified graft stenoses may lack haemodynamic significance, that AR can markedly reduce effective output through blind-loop circulation, and that RV maladaptation at higher pump speeds may remain unnoticed by standard monitoring.  

Place, publisher, year, edition, pages
Linköping: Linköping University Electronic Press, 2025. p. 73
Series
Linköping University Medical Dissertations, ISSN 0345-0082 ; 1999
National Category
Cardiology and Cardiovascular Disease
Identifiers
urn:nbn:se:liu:diva-218257 (URN)10.3384/9789181182545 (DOI)9789181182538 (ISBN)9789181182545 (ISBN)
Public defence
2025-11-06, Granitsalen, building 440, Campus US, Linköping, 13:00 (English)
Opponent
Supervisors
Note

Funding: This work has been conducted in collaboration with the Center for Medical Image Science and Visualization (CMIV) at Linköping University, Sweden. CMIV is acknowledged for the provision of financial support and research infrastructure.

The computations were enabled by resources provided by the National Academic Infrastructure for Supercomputing in Sweden (NAISS), the Swedish National Infrastructure for Computing (SNIC), and the National Supercomputer Centre (NSC). 

Furthermore, the Foundation Linköpings Läkarsällskap and Region Östergötland are acknowledged for financial support.

Available from: 2025-10-02 Created: 2025-10-02 Last updated: 2025-10-02Bibliographically approved

Open Access in DiVA

fulltext(3280 kB)143 downloads
File information
File name FULLTEXT01.pdfFile size 3280 kBChecksum SHA-512
0bba68087f2c38ffef7d776a8047a59e87fc76d412e4a80450da2818aa82c17b4cc4b04f379e701007fa59ea85f5ba39868cc3d75ca4d8ffb1758f2049cc7965
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Konst, BenteOhlsson, LinusHenriksson, LilianSandstedt, MårtenPersson, AndersEbbers, Tino
By organisation
Division of Diagnostics and Specialist MedicineFaculty of Medicine and Health SciencesCenter for Medical Image Science and Visualization (CMIV)Department of Thoracic and Vascular SurgeryDepartment of Radiology in Linköping
In the same journal
Journal of Applied Clinical Medical Physics
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 146 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 231 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf