liu.seSearch for publications in DiVA
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
The influence of undetected hemolysis on POCT potassium results in the emergency department
Erasmus MC, Netherlands.
Hosp Univ La Paz, Spain.
Univ Antwerp, Belgium.
Guys & St Thomas NHS Trust, England.
Show others and affiliations
2024 (English)In: Clinical Chemistry and Laboratory Medicine, ISSN 1434-6621, E-ISSN 1437-4331, Vol. 62, no 11, p. 2169-2176Article in journal (Refereed) Published
Abstract [en]

Objectives This study aimed to evaluate discrepancies in potassium measurements between point-of-care testing (POCT) and central laboratory (CL) methods, focusing on the impact of hemolysis on these measurements and its impact in the clinical practice in the emergency department (ED). Methods A retrospective analysis was conducted using data from three European university hospitals: Technische Universitat Munchen (Germany), Hospital Universitario La Paz (Spain), and Erasmus University Medical Center (The Netherlands). The study compared POCT potassium measurements in EDs with CL measurements. Data normalization was performed in categories for potassium levels (kalemia) and hemolysis. The severity of discrepancies between POCT and CL potassium measurements was assessed using the reference change value (RCV). Results The study identified significant discrepancies in potassium between POCT and CL methods. In comparing POCT normo- and mild hypokalemia against CL results, differences of -4.20 % and +4.88 % were noted respectively. The largest variance in the CL was a +4.14 % difference in the mild hyperkalemia category. Additionally, the RCV was calculated to quantify the severity of discrepancies between paired potassium measurements from POCT and CL methods. The overall hemolysis characteristics, as defined by the hemolysis gradient, showed considerable variation between the testing sites, significantly affecting the reliability of potassium measurements in POCT. Conclusions The study highlighted the challenges in achieving consistent potassium measurement results between POCT and CL methods, particularly in the presence of hemolysis. It emphasised the need for integrated hemolysis detection systems in future blood gas analysis devices to minimise discrepancies and ensure accurate POCT results.

Place, publisher, year, edition, pages
WALTER DE GRUYTER GMBH , 2024. Vol. 62, no 11, p. 2169-2176
Keywords [en]
point-of-care testing (POCT); blood gas analysis (BGA); preanalytical error; hemolysis; potassium
National Category
Medical Laboratory Technologies
Identifiers
URN: urn:nbn:se:liu:diva-203750DOI: 10.1515/cclm-2024-0202ISI: 001218094300001PubMedID: 38726766Scopus ID: 2-s2.0-85193273320OAI: oai:DiVA.org:liu-203750DiVA, id: diva2:1861481
Available from: 2024-05-28 Created: 2024-05-28 Last updated: 2025-04-07Bibliographically approved

Open Access in DiVA

fulltext(565 kB)125 downloads
File information
File name FULLTEXT01.pdfFile size 565 kBChecksum SHA-512
a5d8804efce7950c9556424073c63a9773b967986dd7c402ee0757638f123d2ef39c1fd1d0d9d9576f0a80e3f6a1f80469ba79835f877d33c8fb9f00a007515a
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Schilling, Martin
By organisation
Division of Diagnostics and Specialist MedicineFaculty of Medicine and Health SciencesJourcentralen Linköping
In the same journal
Clinical Chemistry and Laboratory Medicine
Medical Laboratory Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 125 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 116 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf