Automated region growing-based segmentation for trabecular bone structure in fresh-frozen human wrist specimens
Linköping University, Department of Health, Medicine and Caring Sciences, Division of Diagnostics and Specialist Medicine. Linköping University, Faculty of Medicine and Health Sciences. Region Östergötland, Center for Diagnostics, Department of Radiology in Linköping. Linköping University, Center for Medical Image Science and Visualization (CMIV).ORCID iD: 0000-0003-0884-899X
KTH Royal Inst Technol, Sweden.
KTH Royal Inst Technol, Sweden.
KTH Royal Inst Technol, Sweden.
2024 (English)In: BMC Medical Imaging, E-ISSN 1471-2342, Vol. 24, no 1, article id 101Article in journal (Refereed) Published
Abstract [en]

Bone strength depends on both mineral content and bone structure. Measurements of bone microstructure on specimens can be performed by micro-CT. In vivo measurements are reliably performed by high-resolution peripheral computed tomography (HR-pQCT) using dedicated software. In previous studies from our research group, trabecular bone properties on CT data of defatted specimens from many different CT devices have been analyzed using an Automated Region Growing (ARG) algorithm-based code, showing strong correlations to micro-CT.The aim of the study was to validate the possibility of segmenting and measuring trabecular bone structure from clinical CT data of fresh-frozen human wrist specimens. Data from micro-CT was used as reference. The hypothesis was that the ARG-based in-house built software could be used for such measurements.HR-pQCT image data at two resolutions (61 and 82 mu m isotropic voxels) from 23 fresh-frozen human forearms were analyzed. Correlations to micro-CT were strong, varying from 0.72 to 0.99 for all parameters except trabecular termini and nodes. The bone volume fraction had correlations varying from 0.95 to 0.98 but was overestimated compared to micro-CT, especially at the lower resolution. Trabecular separation and spacing were the most stable parameters with correlations at 0.80-0.97 and mean values in the same range as micro-CT.Results from this in vitro study show that an ARG-based software could be used for segmenting and measuring 3D trabecular bone structure from clinical CT data of fresh-frozen human wrist specimens using micro-CT data as reference. Over-and underestimation of several of the bone structure parameters must however be taken into account.

Place, publisher, year, edition, pages
BMC , 2024. Vol. 24, no 1, article id 101
Keywords [en]
Trabecular Bone; Bone Structure Analysis; Segmentation; Micro-CT
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:liu:diva-203763DOI: 10.1186/s12880-024-01281-wISI: 001220792200001PubMedID: 38693510OAI: oai:DiVA.org:liu-203763DiVA, id: diva2:1862114
Note

Funding Agencies|Region stergtland

Available from: 2024-05-29 Created: 2024-05-29 Last updated: 2025-04-07

Open Access in DiVA

fulltext(3065 kB)86 downloads
File information
File name FULLTEXT01.pdfFile size 3065 kBChecksum SHA-512
49f68ff2e6aa315f242cdfbf0bb3db5a1900fcb7b08e787559b2a30ba7c191eef31a570a6c30eff9c83b4690917771d5ffeeb7da50009c326c2f2191c3382eb0
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Klintström, Eva
By organisation
Division of Diagnostics and Specialist MedicineFaculty of Medicine and Health SciencesDepartment of Radiology in LinköpingCenter for Medical Image Science and Visualization (CMIV)
In the same journal
BMC Medical Imaging
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 88 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 98 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • oxford
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf